Worked example
Example: Repeating 50 % stage: 280 m/s, 160 m/s, 25 deg inlet, 25 K. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Mean blade speed | 280.00 m/s |
| Axial velocity | 160.00 m/s |
| Air angle entering the rotor (0 = axial) | 25.000 ° |
| Stage stagnation temperature rise | 25.000 K |
| Work-done factor | 88.000 % |
| Air specific heat | 1.0050 kJ/(kg·K) |
| Ratio of specific heats | 1.4000 - |
| Stage inlet stagnation temperature | 86.850 °C |
| Stage inlet stagnation pressure | 1.8000 bar |
| Stage isentropic efficiency | 90.000 % |
Applying the formula below gives:
| Result | Value |
|---|---|
| Whirl velocity change | 101.97 m/s |
| Whirl velocity leaving the rotor | 176.58 m/s |
| Rotor inlet relative angle | 52.081 ° |
| Rotor outlet relative angle | 32.878 ° |
| Air angle leaving the rotor | 47.820 ° |
| Rotor deflection | 19.203 ° |
| de Haller number (keep at or above 0.72) | 0.73175 |
| Degree of reaction | 55.145 % |
| Flow coefficient C_a/U | 0.57143 |
| Stage loading c_pΔT₀/U² | 0.32047 |
| Stage pressure ratio | 1.2364 |
| Stage exit stagnation pressure | 2.2255 bar |
| Stage exit stagnation temperature | 385.00 K |
| Relative velocity entering the rotor | 260.36 m/s |
| Relative Mach number at rotor inlet | 0.69962 |
Open this example in the calculator and change any input.
Formula
\(\Delta T_{0s} = \frac{\lambda U(C_{w2} - C_{w1})}{c_p} = \frac{\lambda UC_a(\tan\beta_1 - \tan\beta_2)}{c_p}, \quad \tan\beta = \frac{U - C_w}{C_a}\)
\(\frac{V_2}{V_1} = \frac{\cos\beta_1}{\cos\beta_2}, \quad \Lambda = 1 - \frac{C_{w1} + C_{w2}}{2U}, \quad \frac{p_{03}}{p_{01}} = \left(1 + \frac{\eta_s\Delta T_{0s}}{T_{01}}\right)^{\gamma/(\gamma-1)}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(U\) | Mean blade speed | m/s |
| \(C_a\) | Axial velocity | m/s |
| \(\alpha_1\) | Air angle entering the rotor (0 = axial) | rad |
| \(\Delta T_{0s}\) | Stage stagnation temperature rise | K |
| \(\lambda\) | Work-done factor | - |
| \(c_p\) | Air specific heat | J/(kg·K) |
| \(\gamma\) | Ratio of specific heats | - |
| \(T_{01}\) | Stage inlet stagnation temperature | K |
| \(p_{01}\) | Stage inlet stagnation pressure | Pa |
| \(\eta_s\) | Stage isentropic efficiency | - |
| \(\Delta C_w\) | Whirl velocity change | m/s |
| \(C_{w2}\) | Whirl velocity leaving the rotor | m/s |
| \(\beta_1\) | Rotor inlet relative angle | rad |
| \(\beta_2\) | Rotor outlet relative angle | rad |
| \(\alpha_2\) | Air angle leaving the rotor | rad |
| \(\beta_1 - \beta_2\) | Rotor deflection | rad |
| \(V_2/V_1\) | de Haller number (keep at or above 0.72) | - |
| \(\Lambda\) | Degree of reaction | - |
| \(\phi\) | Flow coefficient C_a/U | - |
| \(\psi\) | Stage loading c_pΔT₀/U² | - |
| \(p_{03}/p_{01}\) | Stage pressure ratio | - |
| \(p_{03}\) | Stage exit stagnation pressure | Pa |
| \(T_{03}\) | Stage exit stagnation temperature | K |
| \(V_1\) | Relative velocity entering the rotor | m/s |
| \(M_{V1}\) | Relative Mach number at rotor inlet | - |
Method and standards
Mean-line axial compressor stage design.
Where it is used
- Preliminary design of axial compressors for gas turbines and process air.
- Checking stage loading in compressor rerates.
Common mistakes
- Forgetting the work-done factor.
- Quoting reaction for a non-repeating first stage without noting the approximation.
Assumptions and limits
- Mean radius only; constant axial velocity.
Questions and answers
What is the de Haller number?
The ratio of relative velocities leaving and entering the rotor, V₂/V₁. Below about 0.72 the diffusion is too great and the blades are likely to stall.
What is the work-done factor?
A factor below 1 that allows for the axial velocity profile thickening through the compressor, so a stage absorbs less work than the mean-line velocity triangle suggests. Designers use 0.98 for the first stage, falling to 0.83 for the later stages.
What do the defaults represent?
An illustrative case: Repeating 50 % stage: 280 m/s, 160 m/s, 25 deg inlet, 25 K. Replace the inputs with your own data.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Saravanamuttoo, Rogers and Cohen, Gas Turbine Theory, 4th ed. (Longman, 1996), sec. 5.2-5.6, eq. 5.9 and the seven-stage design example