Axial Compressor Stage: Velocity Triangles, de Haller and Reaction

Blade and air angles, de Haller number, degree of reaction and stage pressure ratio of an axial compressor stage from blade speed and temperature rise.

Thermal power plantProcess steam and utilitiesRefinery and petrochemicalChemical and fertiliser

Inputs

Examples: Repeating 50 % stage: 280 m/s, 160 m/s, 25 deg inlet, 25 KHeavily loaded stage 300 m/s, 150 m/s, 10 deg, 40 K (de Haller below 0.72)

Accepted: 50 to 600 m/s
Accepted: 20 to 300 m/s
Accepted: -57.296 to 68.755 °
Accepted: 1 to 100 K
Accepted: 70 to 100 %
Accepted: 0.9 to 1.2 kJ/(kg·K)
Accepted: 1.2 to 1.67
Accepted: -73.15 to 626.85 °C
Accepted: 0.1 to 50 bar
Accepted: 50 to 100 %

Results

Mean-line design with constant axial velocity (C_a1 = C_a2). Reaction from 1 − (C_w1 + C_w2)/2U assumes the stage outlet velocity equals the inlet velocity (a repeating stage).

Whirl velocity change101.97m/s
Whirl velocity leaving the rotor176.58m/s
Rotor inlet relative angle52.081°
Rotor outlet relative angle32.878°
Air angle leaving the rotor47.820°
Rotor deflection19.203°
de Haller number (keep at or above 0.72)0.73175
Degree of reaction55.145%
Flow coefficient C_a/U0.57143
Stage loading c_pΔT₀/U²0.32047
Stage pressure ratio1.2364
Stage exit stagnation pressure2.2255bar
Stage exit stagnation temperature385.00K
Relative velocity entering the rotor260.36m/s
Relative Mach number at rotor inlet0.69962

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Repeating 50 % stage: 280 m/s, 160 m/s, 25 deg inlet, 25 K. The inputs, in the units selected above:

InputValue
Mean blade speed280.00 m/s
Axial velocity160.00 m/s
Air angle entering the rotor (0 = axial)25.000 °
Stage stagnation temperature rise25.000 K
Work-done factor88.000 %
Air specific heat1.0050 kJ/(kg·K)
Ratio of specific heats1.4000 -
Stage inlet stagnation temperature86.850 °C
Stage inlet stagnation pressure1.8000 bar
Stage isentropic efficiency90.000 %

Applying the formula below gives:

ResultValue
Whirl velocity change101.97 m/s
Whirl velocity leaving the rotor176.58 m/s
Rotor inlet relative angle52.081 °
Rotor outlet relative angle32.878 °
Air angle leaving the rotor47.820 °
Rotor deflection19.203 °
de Haller number (keep at or above 0.72)0.73175
Degree of reaction55.145 %
Flow coefficient C_a/U0.57143
Stage loading c_pΔT₀/U²0.32047
Stage pressure ratio1.2364
Stage exit stagnation pressure2.2255 bar
Stage exit stagnation temperature385.00 K
Relative velocity entering the rotor260.36 m/s
Relative Mach number at rotor inlet0.69962

Open this example in the calculator and change any input.

Formula

\(\Delta T_{0s} = \frac{\lambda U(C_{w2} - C_{w1})}{c_p} = \frac{\lambda UC_a(\tan\beta_1 - \tan\beta_2)}{c_p}, \quad \tan\beta = \frac{U - C_w}{C_a}\)

\(\frac{V_2}{V_1} = \frac{\cos\beta_1}{\cos\beta_2}, \quad \Lambda = 1 - \frac{C_{w1} + C_{w2}}{2U}, \quad \frac{p_{03}}{p_{01}} = \left(1 + \frac{\eta_s\Delta T_{0s}}{T_{01}}\right)^{\gamma/(\gamma-1)}\)

Variables

Symbol Meaning SI unit
\(U\) Mean blade speed m/s
\(C_a\) Axial velocity m/s
\(\alpha_1\) Air angle entering the rotor (0 = axial) rad
\(\Delta T_{0s}\) Stage stagnation temperature rise K
\(\lambda\) Work-done factor -
\(c_p\) Air specific heat J/(kg·K)
\(\gamma\) Ratio of specific heats -
\(T_{01}\) Stage inlet stagnation temperature K
\(p_{01}\) Stage inlet stagnation pressure Pa
\(\eta_s\) Stage isentropic efficiency -
\(\Delta C_w\) Whirl velocity change m/s
\(C_{w2}\) Whirl velocity leaving the rotor m/s
\(\beta_1\) Rotor inlet relative angle rad
\(\beta_2\) Rotor outlet relative angle rad
\(\alpha_2\) Air angle leaving the rotor rad
\(\beta_1 - \beta_2\) Rotor deflection rad
\(V_2/V_1\) de Haller number (keep at or above 0.72) -
\(\Lambda\) Degree of reaction -
\(\phi\) Flow coefficient C_a/U -
\(\psi\) Stage loading c_pΔT₀/U² -
\(p_{03}/p_{01}\) Stage pressure ratio -
\(p_{03}\) Stage exit stagnation pressure Pa
\(T_{03}\) Stage exit stagnation temperature K
\(V_1\) Relative velocity entering the rotor m/s
\(M_{V1}\) Relative Mach number at rotor inlet -

Method and standards

Mean-line axial compressor stage design.

Where it is used

  • Preliminary design of axial compressors for gas turbines and process air.
  • Checking stage loading in compressor rerates.

Common mistakes

  • Forgetting the work-done factor.
  • Quoting reaction for a non-repeating first stage without noting the approximation.

Assumptions and limits

  • Mean radius only; constant axial velocity.

Questions and answers

What is the de Haller number?

The ratio of relative velocities leaving and entering the rotor, V₂/V₁. Below about 0.72 the diffusion is too great and the blades are likely to stall.

What is the work-done factor?

A factor below 1 that allows for the axial velocity profile thickening through the compressor, so a stage absorbs less work than the mean-line velocity triangle suggests. Designers use 0.98 for the first stage, falling to 0.83 for the later stages.

What do the defaults represent?

An illustrative case: Repeating 50 % stage: 280 m/s, 160 m/s, 25 deg inlet, 25 K. Replace the inputs with your own data.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Saravanamuttoo, Rogers and Cohen, Gas Turbine Theory, 4th ed. (Longman, 1996), sec. 5.2-5.6, eq. 5.9 and the seven-stage design example

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.