FireCADCalc

Axial Turbine Stage: Gas Angles, Reaction, Loading and Throat Area

Rotor gas angles, degree of reaction, loading coefficient, power and nozzle throat area (choked or not) of an axial gas turbine stage from its velocity triangles.

Thermal power plantProcess steam and utilitiesRefinery and petrochemicalChemical and fertiliser

Inputs

Examples: Industrial HP stage 300 m/s, 200 m/s, 70 and 0 deg, 100 kg/s

Accepted: 50 to 700 m/s
Accepted: 20 to 500 m/s
Accepted: 5.7296 to 83.079 °
Accepted: -40.107 to 40.107 °
Accepted: 0.01 to 2,000 kg/s
Accepted: 126.85 to 1,926.8 °C
Accepted: 0.1 to 60 bar
Accepted: 0 to 30 %
Accepted: 0.9 to 1.4 kJ/(kg·K)
Accepted: 1.2 to 1.67
Accepted: 0.25 to 0.32 kJ/(kg·K)

Results

Mean-line stage with constant axial velocity and equal inlet and outlet velocities (C₁ = C₃). Throat area ignores the effect of friction on the critical conditions, as in the textbook.

Rotor inlet gas angle51.284°
Rotor outlet gas angle56.310°
Degree of reaction8.4174%
Flow coefficient C_a/U0.66667
Temperature drop coefficient 2c_pΔT₀/U²3.6633
Stage stagnation temperature drop143.60K
Stage power16,485kW
Nozzle exit velocity584.76m/s
Relative velocity entering the rotor319.76m/s
Relative velocity leaving the rotor360.56m/s
Nozzle exit static temperature1,251.1K
Nozzle exit static pressure9.2951bar
Nozzle pressure ratio1.6138
Nozzles choked (1 = yes, 0 = no)0
Annulus area at nozzle exit0.19314m²
Nozzle throat area0.066059m²
Relative Mach number at rotor inlet0.46214

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Industrial HP stage 300 m/s, 200 m/s, 70 and 0 deg, 100 kg/s. The inputs, in the units selected above:

InputValue
Mean blade speed300.00 m/s
Axial velocity (constant)200.00 m/s
Nozzle efflux angle (from axial)70.000 °
Stage exit swirl angle0 °
Gas flow100.00 kg/s
Inlet stagnation temperature1,126.8 °C
Inlet stagnation pressure15.000 bar
Nozzle loss coefficient6.0000 %
Gas specific heat1.1480 kJ/(kg·K)
Gas ratio of specific heats1.3333 -
Gas constant0.28700 kJ/(kg·K)

Applying the formula below gives:

ResultValue
Rotor inlet gas angle51.284 °
Rotor outlet gas angle56.310 °
Degree of reaction8.4174 %
Flow coefficient C_a/U0.66667
Temperature drop coefficient 2c_pΔT₀/U²3.6633
Stage stagnation temperature drop143.60 K
Stage power16,485 kW
Nozzle exit velocity584.76 m/s
Relative velocity entering the rotor319.76 m/s
Relative velocity leaving the rotor360.56 m/s
Nozzle exit static temperature1,251.1 K
Nozzle exit static pressure9.2951 bar
Nozzle pressure ratio1.6138
Nozzles choked (1 = yes, 0 = no)0
Annulus area at nozzle exit0.19314 m²
Nozzle throat area0.066059 m²
Relative Mach number at rotor inlet0.46214

Open this example in the calculator and change any input.

Formula

\(\tan\beta_2 = \tan\alpha_2 - \frac{U}{C_a}, \quad \tan\beta_3 = \tan\alpha_3 + \frac{U}{C_a}, \quad \Lambda = \frac{C_a}{2U}(\tan\beta_3 - \tan\beta_2)\)

\(\psi = \frac{2c_p\Delta T_{0s}}{U^2} = \frac{2C_a}{U}(\tan\beta_2 + \tan\beta_3), \quad T_2 - T_2' = \lambda_N\frac{C_2^2}{2c_p}\)

Variables

Symbol Meaning SI unit
\(U\) Mean blade speed m/s
\(C_a\) Axial velocity (constant) m/s
\(\alpha_2\) Nozzle efflux angle (from axial) rad
\(\alpha_3\) Stage exit swirl angle rad
\(\dot m\) Gas flow kg/s
\(T_{01}\) Inlet stagnation temperature K
\(p_{01}\) Inlet stagnation pressure Pa
\(\lambda_N\) Nozzle loss coefficient -
\(c_p\) Gas specific heat J/(kg·K)
\(\gamma\) Gas ratio of specific heats -
\(R\) Gas constant J/(kg·K)
\(\beta_2\) Rotor inlet gas angle rad
\(\beta_3\) Rotor outlet gas angle rad
\(\Lambda\) Degree of reaction -
\(\phi\) Flow coefficient C_a/U -
\(\psi\) Temperature drop coefficient 2c_pΔT₀/U² -
\(\Delta T_{0s}\) Stage stagnation temperature drop K
\(P\) Stage power W
\(C_2\) Nozzle exit velocity m/s
\(V_2\) Relative velocity entering the rotor m/s
\(V_3\) Relative velocity leaving the rotor m/s
\(T_2\) Nozzle exit static temperature K
\(p_2\) Nozzle exit static pressure Pa
\(p_{01}/p_2\) Nozzle pressure ratio -
\(\text{choked}\) Nozzles choked (1 = yes, 0 = no) -
\(A_2\) Annulus area at nozzle exit m²
\(A_{2N}\) Nozzle throat area m²
\(M_{V2}\) Relative Mach number at rotor inlet -

Method and standards

Mean-line axial turbine stage design.

Where it is used

  • Preliminary design of gas and expander turbine stages.
  • Checking throat area and choking for a rerate.

Common mistakes

  • Measuring angles from the tangential direction (these are from the axial direction).
  • Forgetting that a choked throat is sized at sonic conditions.

Assumptions and limits

  • Mean radius only; constant axial velocity.

Questions and answers

What do the defaults represent?

An illustrative case: Industrial HP stage 300 m/s, 200 m/s, 70 and 0 deg, 100 kg/s. Replace the inputs with your own data.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Saravanamuttoo, Rogers and Cohen, Gas Turbine Theory, 4th ed. (Longman, 1996), sec. 7.1, eqs. 7.1-7.17, the single-stage design example and problem 7.1

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.