Worked example
Example: Industrial HP stage 300 m/s, 200 m/s, 70 and 0 deg, 100 kg/s. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Mean blade speed | 300.00 m/s |
| Axial velocity (constant) | 200.00 m/s |
| Nozzle efflux angle (from axial) | 70.000 ° |
| Stage exit swirl angle | 0 ° |
| Gas flow | 100.00 kg/s |
| Inlet stagnation temperature | 1,126.8 °C |
| Inlet stagnation pressure | 15.000 bar |
| Nozzle loss coefficient | 6.0000 % |
| Gas specific heat | 1.1480 kJ/(kg·K) |
| Gas ratio of specific heats | 1.3333 - |
| Gas constant | 0.28700 kJ/(kg·K) |
Applying the formula below gives:
| Result | Value |
|---|---|
| Rotor inlet gas angle | 51.284 ° |
| Rotor outlet gas angle | 56.310 ° |
| Degree of reaction | 8.4174 % |
| Flow coefficient C_a/U | 0.66667 |
| Temperature drop coefficient 2c_pΔT₀/U² | 3.6633 |
| Stage stagnation temperature drop | 143.60 K |
| Stage power | 16,485 kW |
| Nozzle exit velocity | 584.76 m/s |
| Relative velocity entering the rotor | 319.76 m/s |
| Relative velocity leaving the rotor | 360.56 m/s |
| Nozzle exit static temperature | 1,251.1 K |
| Nozzle exit static pressure | 9.2951 bar |
| Nozzle pressure ratio | 1.6138 |
| Nozzles choked (1 = yes, 0 = no) | 0 |
| Annulus area at nozzle exit | 0.19314 m² |
| Nozzle throat area | 0.066059 m² |
| Relative Mach number at rotor inlet | 0.46214 |
Open this example in the calculator and change any input.
Formula
\(\tan\beta_2 = \tan\alpha_2 - \frac{U}{C_a}, \quad \tan\beta_3 = \tan\alpha_3 + \frac{U}{C_a}, \quad \Lambda = \frac{C_a}{2U}(\tan\beta_3 - \tan\beta_2)\)
\(\psi = \frac{2c_p\Delta T_{0s}}{U^2} = \frac{2C_a}{U}(\tan\beta_2 + \tan\beta_3), \quad T_2 - T_2' = \lambda_N\frac{C_2^2}{2c_p}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(U\) | Mean blade speed | m/s |
| \(C_a\) | Axial velocity (constant) | m/s |
| \(\alpha_2\) | Nozzle efflux angle (from axial) | rad |
| \(\alpha_3\) | Stage exit swirl angle | rad |
| \(\dot m\) | Gas flow | kg/s |
| \(T_{01}\) | Inlet stagnation temperature | K |
| \(p_{01}\) | Inlet stagnation pressure | Pa |
| \(\lambda_N\) | Nozzle loss coefficient | - |
| \(c_p\) | Gas specific heat | J/(kg·K) |
| \(\gamma\) | Gas ratio of specific heats | - |
| \(R\) | Gas constant | J/(kg·K) |
| \(\beta_2\) | Rotor inlet gas angle | rad |
| \(\beta_3\) | Rotor outlet gas angle | rad |
| \(\Lambda\) | Degree of reaction | - |
| \(\phi\) | Flow coefficient C_a/U | - |
| \(\psi\) | Temperature drop coefficient 2c_pΔT₀/U² | - |
| \(\Delta T_{0s}\) | Stage stagnation temperature drop | K |
| \(P\) | Stage power | W |
| \(C_2\) | Nozzle exit velocity | m/s |
| \(V_2\) | Relative velocity entering the rotor | m/s |
| \(V_3\) | Relative velocity leaving the rotor | m/s |
| \(T_2\) | Nozzle exit static temperature | K |
| \(p_2\) | Nozzle exit static pressure | Pa |
| \(p_{01}/p_2\) | Nozzle pressure ratio | - |
| \(\text{choked}\) | Nozzles choked (1 = yes, 0 = no) | - |
| \(A_2\) | Annulus area at nozzle exit | m² |
| \(A_{2N}\) | Nozzle throat area | m² |
| \(M_{V2}\) | Relative Mach number at rotor inlet | - |
Method and standards
Mean-line axial turbine stage design.
Where it is used
- Preliminary design of gas and expander turbine stages.
- Checking throat area and choking for a rerate.
Common mistakes
- Measuring angles from the tangential direction (these are from the axial direction).
- Forgetting that a choked throat is sized at sonic conditions.
Assumptions and limits
- Mean radius only; constant axial velocity.
Questions and answers
What do the defaults represent?
An illustrative case: Industrial HP stage 300 m/s, 200 m/s, 70 and 0 deg, 100 kg/s. Replace the inputs with your own data.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Saravanamuttoo, Rogers and Cohen, Gas Turbine Theory, 4th ed. (Longman, 1996), sec. 7.1, eqs. 7.1-7.17, the single-stage design example and problem 7.1