FireCADCalc

Turbine Blade Height from Steam Flow, Mean Diameter and Admission

Blade (nozzle) height needed to pass a steam flow at a mean diameter, axial velocity and arc of admission, with blade speed from diameter and rpm.

Thermal power plantProcess steam and utilitiesSugar mill and cogenerationPulp and paper

Inputs

Examples: 50 t/h, 0.25 m3/kg, 0.8 m, 3,000 rpm, full admissionHP stage 100 t/h, 0.03 m3/kg, 0.9 m, 30 % admissionLP stage 300 t/h, 8 m3/kg, 2.0 m

Accepted: 0.036 to 7,200 t/h
Accepted: 0.001 to 100 m³/kg
Accepted: 0.1 to 5 m
Accepted: 95.493 to 19,099 rpm
Accepted: 10 to 2,000 m/s
Accepted: 2.8648 to 85.944 °
Accepted: 1 to 100 %
Accepted: 50 to 100 %

Results

Mean blade speed125.66m/s
Axial velocity92.705m/s
Flow area needed0.13484m²
Blade height59.611mm
Height-to-diameter ratio0.074513
Velocity ratio0.41888

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 50 t/h, 0.25 m3/kg, 0.8 m, 3,000 rpm, full admission. The inputs, in the units selected above:

InputValue
Steam flow50.000 t/h
Specific volume at the blade row0.25000 m³/kg
Mean blade diameter0.80000 m
Speed3,000.0 rpm
Steam velocity leaving the nozzles300.00 m/s
Nozzle exit angle18.000 °
Arc of admission (1 = full)100.00 %
Blade blockage factor (thickness), about 0.990.000 %

Applying the formula below gives:

ResultValue
Mean blade speed125.66 m/s
Axial velocity92.705 m/s
Flow area needed0.037454 m²
Blade height16.559 mm
Height-to-diameter ratio0.020698
Velocity ratio0.41888

Open this example in the calculator and change any input.

Formula

\(A = \frac{\dot m v}{V_1\sin\alpha}, \quad h_b = \frac{A}{\pi D_m\varepsilon k}, \quad V_b = \frac{\pi D_mN}{60}\)

Variables

Symbol Meaning SI unit
\(\dot m\) Steam flow kg/s
\(v\) Specific volume at the blade row m³/kg
\(D_m\) Mean blade diameter m
\(N\) Speed rad/s
\(V_1\) Steam velocity leaving the nozzles m/s
\(\alpha\) Nozzle exit angle rad
\(\varepsilon\) Arc of admission (1 = full) -
\(k\) Blade blockage factor (thickness), about 0.9 -
\(V_b\) Mean blade speed m/s
\(V_a\) Axial velocity m/s
\(A\) Flow area needed m²
\(h_b\) Blade height m
\(h_b/D_m\) Height-to-diameter ratio -
\(V_b/V_1\) Velocity ratio -

Method and standards

Continuity through the blade annulus.

Where it is used

  • Preliminary stage layout.
  • Checking blade heights for a new flow.

Common mistakes

  • Using the absolute velocity instead of its axial component.
  • Forgetting the arc of admission.

Assumptions and limits

  • Uniform flow at mean diameter.

Questions and answers

Why partial admission?

In HP stages the specific volume is small; with full admission the blades would be only a few millimetres tall, so nozzles are fitted round part of the circumference to keep a reasonable blade height.

Why does the blade height grow through the turbine?

Specific volume rises a hundredfold or more from inlet to condenser, so the annulus must grow; LP blades are the longest.

What do the defaults represent?

50 t/h with 0.25 m³/kg at 0.8 m mean diameter and 3,000 rpm, 300 m/s at 18° and full admission: 126 m/s blade speed, 92.7 m/s axial velocity, 0.0375 m² and 16.6 mm blades with 0.9 blockage.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Nag, Power Plant Engineering, 3rd ed. (Tata McGraw-Hill, 2008), sec. 7.3, eq. 7.41 (annulus area π D_m h_b) with continuity

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.