Worked example
Example: Illustrative 200 MW unit. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Shaft-line moment of inertia | 35,000 kg·m² |
| Rated speed | 3,000.0 rpm |
| Power before the rejection | 200.00 MW |
| Effective valve closing time | 0.30000 s |
| Steam trapped downstream of the valves | 400.00 kg |
| Usable enthalpy drop of trapped steam | 300.00 kJ/kg |
| Expansion efficiency | 75.000 % |
Applying the formula below gives:
| Result | Value |
|---|---|
| Energy during valve closure | 30.000 MJ |
| Energy from trapped steam | 90.000 MJ |
| Kinetic energy at rated speed | 1,727.2 MJ |
| Peak speed | 3,102.5 rpm |
| Overspeed | 3.4155 % |
Open this example in the calculator and change any input.
Formula
\(E = \frac{Pt_c}{2} + m_{tr}\Delta h\eta, \quad \omega_{max} = \sqrt{\omega^2 + \frac{2E}{J}}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(J\) | Shaft-line moment of inertia | kg·m² |
| \(n\) | Rated speed | rad/s |
| \(P\) | Power before the rejection | W |
| \(t_c\) | Effective valve closing time | s |
| \(m_{tr}\) | Steam trapped downstream of the valves | kg |
| \(\Delta h\) | Usable enthalpy drop of trapped steam | J/kg |
| \(\eta\) | Expansion efficiency | - |
| \(E_v\) | Energy during valve closure | J |
| \(E_{tr}\) | Energy from trapped steam | J |
| \(E_0\) | Kinetic energy at rated speed | J |
| \(n_{max}\) | Peak speed | rad/s |
| \(n_{max}/n - 1\) | Overspeed | - |
Method and standards
Overspeed.
Where it is used
- Turbine protection reviews.
- Effect of extraction non-return valves.
Common mistakes
- Ignoring extraction line steam flowing back.
- Using GD² without converting to J.
Assumptions and limits
- No losses or windage; linear valve closure.
References
- Rotor energy balance after load rejection
Questions and answers
Why does trapped steam matter?
Steam already past the stop and control valves keeps expanding through the turbine, driving the unloaded rotor faster.
How is overspeed limited?
Fast-closing stop, control and intercept valves, small trapped volumes and non-return valves on extractions.
What do the defaults represent?
An illustrative 200 MW unit at 3,000 rpm with J = 35,000 kg·m², 0.3 s effective closing time and 400 kg of trapped steam with 300 kJ/kg usable at 75 % efficiency.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Leizerovich, Steam Turbines for Modern Fossil-Fuel Power Plants (Fairmont Press, 2008)