FireCADCalc

Curtis (Velocity-compounded) Stage and Number of Stages Needed

Optimum velocity ratio, diagram efficiency, row work split and isentropic drop of a Curtis stage, compared with impulse and reaction stages and stages needed.

Thermal power plantProcess steam and utilitiesSugar mill and cogenerationPulp and paper

Inputs

Examples: Three rows, 250 m/s, 15 deg, optimumSimple impulse 300 m/s, 20 deg, rho 0.4

Accepted: 10 to 600 m/s
Accepted: 2.8648 to 74.485 °
Accepted: 0 to 1
Accepted: 1 to 3,000 kJ/kg

Results

Frictionless, symmetric blades and axial discharge, in the derivation; real Curtis stages lose much more to blade friction, which is why they are used only as a first (control) stage. The work split 3: 1 (two rows) or 5: 3: 1 (three rows) holds at the optimum ratio cos α/2Z.

Velocity ratio used0.16099
Nozzle exit velocity1,552.9m/s
Diagram efficiency (frictionless, symmetric)93.301%
Diagram work per kg1,125.0kJ/kg
Isentropic drop of this stage1,205.8kJ/kg
Drop of a simple impulse stage at optimum133.97kJ/kg
Drop of a 50 % reaction stage at optimum66.987kJ/kg
Stages of this type for the total drop2.0000
Share of work on the first row55.556%

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Three rows, 250 m/s, 15 deg, optimum. The inputs, in the units selected above:

InputValue
Mean blade speed250.00 m/s
Nozzle angle15.000 °
Rows of moving blades3 (three-row Curtis)
Velocity ratio V_b/V_1 (0 for the optimum)0 -
Total isentropic drop to be handled2,000.0 kJ/kg

Applying the formula below gives:

ResultValue
Velocity ratio used0.16099
Nozzle exit velocity1,552.9 m/s
Diagram efficiency (frictionless, symmetric)93.301 %
Diagram work per kg1,125.0 kJ/kg
Isentropic drop of this stage1,205.8 kJ/kg
Drop of a simple impulse stage at optimum133.97 kJ/kg
Drop of a 50 % reaction stage at optimum66.987 kJ/kg
Stages of this type for the total drop2.0000
Share of work on the first row55.556 %

Open this example in the calculator and change any input.

Formula

\(\rho_{opt} = \frac{\cos\alpha}{2Z}, \quad \eta_D = 4Z\rho(\cos\alpha - Z\rho), \quad (\eta_D)_{max} = \cos^2\alpha, \quad \Delta h_s = \frac{V_1^2}{2}\)

\((\Delta h_s)_{50\%} : (\Delta h_s)_{imp} : (\Delta h_s)_{Curtis,2} = 1 : 2 : 8, \quad n = \left\lceil\frac{(\Delta h_s)_{total}}{\Delta h_s}\right\rceil\)

Variables

Symbol Meaning SI unit
\(V_b\) Mean blade speed m/s
\(\alpha\) Nozzle angle rad
\(Z\) Rows of moving blades -
\(\rho\) Velocity ratio V_b/V_1 (0 for the optimum) -
\((\Delta h_s)_{total}\) Total isentropic drop to be handled J/kg
\(V_1\) Nozzle exit velocity m/s
\(\eta_D\) Diagram efficiency (frictionless, symmetric) -
\(W_D\) Diagram work per kg J/kg
\(\Delta h_s\) Isentropic drop of this stage J/kg
\((\Delta h_s)_{imp}\) Drop of a simple impulse stage at optimum J/kg
\((\Delta h_s)_{50\%}\) Drop of a 50 % reaction stage at optimum J/kg
\(n\) Stages of this type for the total drop -
\(W_1/W_D\) Share of work on the first row -

Method and standards

Velocity-compounded impulse stage theory.

Where it is used

  • Choosing the control stage type.
  • Estimating stage counts in preliminary design.

Common mistakes

  • Using the simple-impulse optimum ratio cos α/2 for a two-row wheel.
  • Ignoring friction, which makes real Curtis stages far less efficient.

Assumptions and limits

  • Frictionless symmetric blades; axial discharge.

Questions and answers

Why use a Curtis stage?

It absorbs a large enthalpy drop at modest blade speed, so the pressure and temperature fall quickly before the casing; it is common as the control stage of industrial turbines.

How do the stage types compare?

At the same blade speed and nozzle angle the ideal drops are 1 : 2 : 8 for 50 % reaction, simple impulse and two-row Curtis stages.

What do the defaults represent?

An illustrative case: Three rows, 250 m/s, 15 deg, optimum. Replace the inputs with your own data.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Nag, Power Plant Engineering, 3rd ed. (Tata McGraw-Hill, 2008), sec. 7.3.1, eqs. 7.63-7.68 and 7.83-7.84

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.