Worked example
Example: 200 t/h at 130 bar(a) 535 C, four heaters, 0.1 bar(a). The inputs, in the units selected above:
| Input | Value |
|---|---|
| Throttle steam flow (= feedwater flow) | 200.00 t/h |
| Throttle pressure (absolute) | 130.00 bar |
| Throttle temperature | 535.00 °C |
| Feedwater pressure through the heaters (absolute) | 160.00 bar |
| Condenser pressure (absolute) | 0.10000 bar |
| Expansion-line (section) isentropic efficiency | 82.000 % |
| Heater 1 | Closed heater, drains cascaded down |
| Heater 1: extraction (shell) pressure, absolute | 40.000 bar |
| Heater 1: terminal temperature difference | 2.0000 K |
| Heater 1: drain cooler approach | 6.0000 K |
| Heater 2 | Closed heater, drains cascaded down |
| Heater 2: extraction (shell) pressure, absolute | 18.000 bar |
| Heater 2: terminal temperature difference | 2.0000 K |
| Heater 2: drain cooler approach | 6.0000 K |
| Heater 3 | Closed heater, drains cascaded down |
| Heater 3: extraction (shell) pressure, absolute | 2.5000 bar |
| Heater 3: terminal temperature difference | 2.5000 K |
| Heater 3: drain cooler approach | 5.5000 K |
| Heater 4 | Closed heater, drains cascaded down |
| Heater 4: extraction (shell) pressure, absolute | 0.70000 bar |
| Heater 4: terminal temperature difference | 3.0000 K |
| Heater 4: drain cooler approach | 5.5000 K |
| Gearbox and generator efficiency | 97.000 % |
Applying the formula below gives:
| Result | Value |
|---|---|
| Heater 1: extraction steam flow | 17.614 t/h |
| Heater 1: extraction enthalpy | 3,142.0 kJ/kg |
| Heater 1: feedwater outlet temperature | 248.36 °C |
| Heater 1: drain outlet temperature | 211.12 °C |
| Heater 2: extraction steam flow | 25.947 t/h |
| Heater 2: extraction enthalpy | 2,975.9 kJ/kg |
| Heater 2: feedwater outlet temperature | 205.12 °C |
| Heater 2: drain outlet temperature | 130.91 °C |
| Heater 3: extraction steam flow | 10.877 t/h |
| Heater 3: extraction enthalpy | 2,656.8 kJ/kg |
| Heater 3: feedwater outlet temperature | 124.91 °C |
| Heater 3: drain outlet temperature | 92.432 °C |
| Heater 4: extraction steam flow | 10.900 t/h |
| Heater 4: extraction enthalpy | 2,487.6 kJ/kg |
| Heater 4: feedwater outlet temperature | 86.932 °C |
| Heater 4: drain outlet temperature | 51.308 °C |
| Steam to the condenser | 134.66 t/h |
| Exhaust dryness | 0.86775 |
| Final feedwater temperature | 248.36 °C |
| Generator output | 51,851 kW |
| Heat added in the boiler | 130,745 kW |
| Turbine cycle heat rate | 9,077.6 kJ/kWh |
| Cycle efficiency | 39.658 % |
| Generator output with no heaters | 59,860 kW |
| Heat rate with no heaters | 10,779 kJ/kWh |
| Heat-rate improvement from the heaters | 15.783 % |
Open this example in the calculator and change any input.
Formula
\(\dot m_j(h_j - h_{d,j}) + D_{j-1}(h_{d,j-1} - h_{d,j}) = \dot m_{fw}(h_{fw,j} - h_{fw,j+1}), \quad T_{fw,j} = T_{sat}(p_j) - TTD_j, \quad T_{d,j} = T_{fw,j+1} + DCA_j\)
\(P_{el} = \eta_g\sum_j\Big(\dot m_0 - \sum_{k<j}\dot m_k\Big)(h_{j-1} - h_j), \quad HR = \frac{\dot m_0(h_0 - h_{fw})}{P_{el}}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\dot m_0\) | Throttle steam flow (= feedwater flow) | kg/s |
| \(p_0\) | Throttle pressure (absolute) | Pa |
| \(T_0\) | Throttle temperature | K |
| \(p_{fw}\) | Feedwater pressure through the heaters (absolute) | Pa |
| \(p_c\) | Condenser pressure (absolute) | Pa |
| \(\eta_t\) | Expansion-line (section) isentropic efficiency | - |
| \(\text{use}_1\) | Heater 1 | - |
| \(p_1\) | Heater 1: extraction (shell) pressure, absolute | Pa |
| \(TTD_1\) | Heater 1: terminal temperature difference | K |
| \(DCA_1\) | Heater 1: drain cooler approach | K |
| \(\text{use}_2\) | Heater 2 | - |
| \(p_2\) | Heater 2: extraction (shell) pressure, absolute | Pa |
| \(TTD_2\) | Heater 2: terminal temperature difference | K |
| \(DCA_2\) | Heater 2: drain cooler approach | K |
| \(\text{use}_3\) | Heater 3 | - |
| \(p_3\) | Heater 3: extraction (shell) pressure, absolute | Pa |
| \(TTD_3\) | Heater 3: terminal temperature difference | K |
| \(DCA_3\) | Heater 3: drain cooler approach | K |
| \(\text{use}_4\) | Heater 4 | - |
| \(p_4\) | Heater 4: extraction (shell) pressure, absolute | Pa |
| \(TTD_4\) | Heater 4: terminal temperature difference | K |
| \(DCA_4\) | Heater 4: drain cooler approach | K |
| \(\eta_g\) | Gearbox and generator efficiency | - |
| \(\dot m_1\) | Heater 1: extraction steam flow | kg/s |
| \(h_1\) | Heater 1: extraction enthalpy | J/kg |
| \(T_{fw,1}\) | Heater 1: feedwater outlet temperature | K |
| \(T_{d,1}\) | Heater 1: drain outlet temperature | K |
| \(\dot m_2\) | Heater 2: extraction steam flow | kg/s |
| \(h_2\) | Heater 2: extraction enthalpy | J/kg |
| \(T_{fw,2}\) | Heater 2: feedwater outlet temperature | K |
| \(T_{d,2}\) | Heater 2: drain outlet temperature | K |
| \(\dot m_3\) | Heater 3: extraction steam flow | kg/s |
| \(h_3\) | Heater 3: extraction enthalpy | J/kg |
| \(T_{fw,3}\) | Heater 3: feedwater outlet temperature | K |
| \(T_{d,3}\) | Heater 3: drain outlet temperature | K |
| \(\dot m_4\) | Heater 4: extraction steam flow | kg/s |
| \(h_4\) | Heater 4: extraction enthalpy | J/kg |
| \(T_{fw,4}\) | Heater 4: feedwater outlet temperature | K |
| \(T_{d,4}\) | Heater 4: drain outlet temperature | K |
| \(\dot m_c\) | Steam to the condenser | kg/s |
| \(x_c\) | Exhaust dryness | - |
| \(T_{fw}\) | Final feedwater temperature | K |
| \(P_{el}\) | Generator output | W |
| \(Q\) | Heat added in the boiler | W |
| \(HR\) | Turbine cycle heat rate | J/J |
| \(\eta_{cyc}\) | Cycle efficiency | - |
| \(P_{el,0}\) | Generator output with no heaters | W |
| \(HR_0\) | Heat rate with no heaters | J/J |
| \(\Delta HR\) | Heat-rate improvement from the heaters | - |
Method and standards
Regenerative feed heating heat balance with IAPWS-IF97.
Where it is used
- Checking extraction flows and heater performance in power and captive plants.
- Effect of a heater out of service or a changed TTD on heat rate.
- Preliminary cycle design.
Common mistakes
- Listing heaters from low to high pressure.
- Using gauge pressures.
- Forgetting the drains cascading from higher heaters.
Assumptions and limits
- Closed heaters only; no deaerator, reheat or make-up; pump work neglected.
Questions and answers
How are the extraction flows found?
From the top heater down: each heater's steam must supply the feedwater temperature rise less the heat brought in by the drains cascading from the heaters above it. The drain leaves each heater DCA above that heater's feedwater inlet temperature.
What sets each heater's outlet temperature?
The shell saturation temperature at the extraction pressure less the terminal temperature difference (TTD). Drain coolers make DCA positive; heaters with a desuperheating zone can have TTD near zero or slightly negative.
Why does feed heating improve heat rate if it costs power?
The extracted steam gives up its latent heat to the feedwater instead of to the condenser, so less fuel heat is needed per kWh even though the turbine makes less power for the same throttle flow.
What do the defaults represent?
200 t/h at 130 bar(a) and 535 °C, four closed heaters at 40, 18, 2.5 and 0.7 bar(a), 0.1 bar(a) condenser, 82 % expansion line: extractions of 17.6, 26.0, 10.9 and 10.9 t/h, final feedwater 248 °C, 51.9 MW and a cycle heat rate of 9,078 kJ/kWh, about 16 % better than with no heaters.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
IAPWS R7-97(2012) IF97 (steam and water properties), Heater energy balances with cascaded drains; turbine section-by-section energy balance