FireCADCalc

Reheat (Sequential Combustion) Gas Turbine Cycle

Specific work, fuel/air ratio, efficiency and exhaust temperature of a single-shaft gas turbine with reheat, from polytropic efficiencies and the reheat pressure.

Thermal power plantProcess steam and utilitiesRefinery and petrochemicalChemical and fertiliser

Inputs

Examples: Ratio 20, 1,450 K and 1,400 K, 30 C day

Accepted: 2 to 60
Accepted: 50 to 100 %
Accepted: 50 to 100 %
Accepted: 426.85 to 1,726.8 °C
Accepted: 426.85 to 1,726.8 °C
Accepted: 0 to 20 %
Accepted: 0 to 20 %
Accepted: 0.5 to 1.1 bar
Accepted: -53.15 to 56.85 °C
Accepted: 0.5 to 1.5 bar
Accepted: 1.05 to 30
Accepted: 80 to 100 %
Accepted: 80 to 100 %
Accepted: 0.9 to 1.2 kJ/(kg·K)
Accepted: 1.2 to 1.67
Accepted: 0.9 to 1.4 kJ/(kg·K)
Accepted: 1.2 to 1.67
Accepted: 10,000 to 120,000 kJ/kg
Accepted: 0 to 4
Accepted: 0.001 to 2,000 MW

Results

Constant mass flow, no cooling bleeds, constant c_p and γ for air and for gas as in the textbook method. The fuel/air ratio of each combustor comes from an enthalpy balance with NIST Shomate data for a CH_y fuel. Equal turbine ratios give the most work; a higher reheat pressure lowers the exhaust temperature and raises efficiency.

Compressor delivery temperature801.41K
Compressor work per kg air500.90kJ/kg
HP turbine inlet pressure19.652bar
Reheat pressure (HP turbine exit)5.6149bar
HP turbine exit temperature1,104.2K
LP turbine inlet pressure5.3903bar
LP turbine pressure ratio5.1830
Equal-split HP ratio (ignoring the reheat loss)4.3470
Exhaust temperature (EGT)978.83K
Net specific work366.42kJ/kg
Total fuel/air ratio0.027742
Specific fuel consumption0.27257kg/kWh
Cycle efficiency (LHV)30.644%
Air flow for the power required654.99kg/s

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Ratio 20, 1,450 K and 1,400 K, 30 C day. The inputs, in the units selected above:

InputValue
Compressor pressure ratio20.000 -
Compressor polytropic efficiency88.000 %
Turbine polytropic efficiency (both turbines)87.000 %
HP turbine inlet temperature1,176.8 °C
LP turbine inlet temperature (after reheat)1,126.8 °C
First combustor pressure loss3.0000 %
Reheat combustor pressure loss4.0000 %
Ambient (compressor inlet) pressure1.0130 bar
Ambient temperature29.850 °C
Turbine exhaust pressure1.0400 bar
HP turbine pressure ratio (sets the reheat pressure)3.5000 -
Mechanical efficiency98.500 %
Combustion efficiency99.500 %
Air specific heat1.0050 kJ/(kg·K)
Air ratio of specific heats1.4000 -
Gas specific heat1.1480 kJ/(kg·K)
Gas ratio of specific heats1.3333 -
Fuel net calorific value43,100 kJ/kg
Fuel H/C atom ratio (kerosene about 1.92, methane 4)1.9200 -
Power required (for the air flow)240.00 MW

Applying the formula below gives:

ResultValue
Compressor delivery temperature801.41 K
Compressor work per kg air500.90 kJ/kg
HP turbine inlet pressure19.652 bar
Reheat pressure (HP turbine exit)5.6149 bar
HP turbine exit temperature1,104.2 K
LP turbine inlet pressure5.3903 bar
LP turbine pressure ratio5.1830
Equal-split HP ratio (ignoring the reheat loss)4.3470
Exhaust temperature (EGT)978.83 K
Net specific work366.42 kJ/kg
Total fuel/air ratio0.027742
Specific fuel consumption0.27257 kg/kWh
Cycle efficiency (LHV)30.644 %
Air flow for the power required654.99 kg/s

Open this example in the calculator and change any input.

Formula

\(\frac{T_{02}}{T_{01}} = r_c^{(\gamma_a-1)/(\gamma_a\eta_{\infty c})}, \quad \frac{T_{03}}{T_{04}} = \left(\frac{p_{03}}{p_{04}}\right)^{\eta_{\infty t}(\gamma_g-1)/\gamma_g}\)

\(W = \eta_m c_{pg}\left[(T_{03} - T_{04}) + (T_{05} - T_{06})\right] - c_{pa}(T_{02} - T_{01}), \quad \eta = \frac{W}{fQ_{net}}\)

Variables

Symbol Meaning SI unit
\(r_c\) Compressor pressure ratio -
\(\eta_{\infty c}\) Compressor polytropic efficiency -
\(\eta_{\infty t}\) Turbine polytropic efficiency (both turbines) -
\(T_{03}\) HP turbine inlet temperature K
\(T_{05}\) LP turbine inlet temperature (after reheat) K
\(\Delta p/p_{02}\) First combustor pressure loss -
\(\Delta p/p_{04}\) Reheat combustor pressure loss -
\(p_a\) Ambient (compressor inlet) pressure Pa
\(T_a\) Ambient temperature K
\(p_{06}\) Turbine exhaust pressure Pa
\(p_{03}/p_{04}\) HP turbine pressure ratio (sets the reheat pressure) -
\(\eta_m\) Mechanical efficiency -
\(\eta_b\) Combustion efficiency -
\(c_{pa}\) Air specific heat J/(kg·K)
\(\gamma_a\) Air ratio of specific heats -
\(c_{pg}\) Gas specific heat J/(kg·K)
\(\gamma_g\) Gas ratio of specific heats -
\(Q_{net}\) Fuel net calorific value J/kg
\(y\) Fuel H/C atom ratio (kerosene about 1.92, methane 4) -
\(P\) Power required (for the air flow) W
\(T_{02}\) Compressor delivery temperature K
\(W_c\) Compressor work per kg air J/kg
\(p_{03}\) HP turbine inlet pressure Pa
\(p_{04}\) Reheat pressure (HP turbine exit) Pa
\(T_{04}\) HP turbine exit temperature K
\(p_{05}\) LP turbine inlet pressure Pa
\(p_{05}/p_{06}\) LP turbine pressure ratio -
\(\sqrt{p_{03}/p_{06}}\) Equal-split HP ratio (ignoring the reheat loss) -
\(T_{06}\) Exhaust temperature (EGT) K
\(W\) Net specific work J/kg
\(f\) Total fuel/air ratio -
\(SFC\) Specific fuel consumption kg/J
\(\eta\) Cycle efficiency (LHV) -
\(\dot m\) Air flow for the power required kg/s

Method and standards

Textbook reheat cycle with polytropic efficiencies and enthalpy-balance fuel/air ratios.

Where it is used

  • Choosing the reheat pressure for a sequential-combustion gas turbine in a combined cycle.
  • Comparing reheat with simple and intercooled cycles.

Common mistakes

  • Splitting the turbine ratios equally when the exhaust heat is to be used.
  • Forgetting the second combustor's pressure loss.

Assumptions and limits

  • Constant flow; no cooling air; constant c_p and γ.

Questions and answers

Why not always use equal turbine pressure ratios?

Equal ratios give the most specific work, but the exhaust is then very hot. For a combined cycle a higher reheat pressure brings the exhaust to about 600 °C and raises the gas turbine efficiency, at about 10 % less specific work.

What do the defaults represent?

An illustrative case: Ratio 20, 1,450 K and 1,400 K, 30 C day. Replace the inputs with your own data.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Saravanamuttoo, Rogers and Cohen, Gas Turbine Theory, 4th ed. (Longman, 1996), sec. 2.3, Example 2.3 and Fig. 2.23; NIST Chemistry WebBook Shomate data for the fuel/air ratios

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.