Worked example
Example: Illustrative ratio 8, 1100 C, 85 % recuperator. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Compressor inlet temperature | 15.000 °C |
| Overall pressure ratio | 8.0000 - |
| Turbine inlet temperature | 1,100.0 °C |
| Compressor isentropic efficiency | 85.000 % |
| Turbine isentropic efficiency | 88.000 % |
| Mean specific heat | 1.1000 kJ/(kg·K) |
| Heat capacity ratio | 1.3600 - |
| Recuperator effectiveness | 85.000 % |
Applying the formula below gives:
| Result | Value |
|---|---|
| Compressor outlet temperature | 263.83 °C |
| Turbine exhaust temperature | 588.49 °C |
| Air to combustor after recuperator | 539.79 °C |
| Net specific work | 288.95 kJ/kg |
| Thermal efficiency, recuperated | 46.889 % |
| Thermal efficiency without recuperator | 31.414 % |
Open this example in the calculator and change any input.
Formula
\(T_5 = T_2 + \varepsilon(T_4 - T_2), \quad \eta = \frac{c_p[(T_3 - T_4) - (T_2 - T_1)]}{c_p(T_3 - T_5)}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(T_1\) | Compressor inlet temperature | K |
| \(r_p\) | Overall pressure ratio | - |
| \(T_3\) | Turbine inlet temperature | K |
| \(\eta_c\) | Compressor isentropic efficiency | - |
| \(\eta_t\) | Turbine isentropic efficiency | - |
| \(c_p\) | Mean specific heat | J/(kg·K) |
| \(\gamma\) | Heat capacity ratio | - |
| \(\varepsilon\) | Recuperator effectiveness | - |
| \(T_2\) | Compressor outlet temperature | K |
| \(T_4\) | Turbine exhaust temperature | K |
| \(T_5\) | Air to combustor after recuperator | K |
| \(w_{net}\) | Net specific work | J/kg |
| \(\eta\) | Thermal efficiency, recuperated | - |
| \(\eta_0\) | Thermal efficiency without recuperator | - |
Method and standards
Recuperated cycle.
Where it is used
- Microturbine and small CHP assessment.
- Comparing cycle options.
Common mistakes
- Recuperating at high pressure ratios.
- Ignoring recuperator pressure drop.
Assumptions and limits
- Constant c_p and γ; no pressure losses; same mass flow throughout.
References
- Air-standard Brayton cycle with recuperation
Questions and answers
Why does recuperation suit low pressure ratios?
At low ratios the turbine exhaust is much hotter than compressor delivery, leaving plenty of heat to recover.
Does a recuperator change net work?
Ideally not; it reduces fuel. Real recuperators add pressure losses that cost a little work.
What do the defaults represent?
An illustrative cycle at pressure ratio 8, 15 °C inlet, 1,100 °C turbine inlet, 85/88 % efficiencies and an 85 % effective recuperator.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Saravanamuttoo, Rogers, Cohen and Straznicky, Gas Turbine Theory, 6th ed. (Pearson, 2009)