Thermal effusivity of two materials and the interface temperature when they touch, which explains why metal feels colder than wood at the same temperature.

Inputs

Examples: Illustrative skin on steel at 20 CSkin on wood at 20 CMolten aluminium on a steel die

Accepted: 0.001 to 5,000 W/(m·K)
Accepted: 1 to 25,000 kg/m³
Accepted: 0.05 to 20 kJ/(kg·K)
Accepted: -272.15 to 2,726.8 °C
Accepted: 0.001 to 5,000 W/(m·K)
Accepted: 1 to 25,000 kg/m³
Accepted: 0.05 to 20 kJ/(kg·K)
Accepted: -272.15 to 2,726.8 °C

Results

Two semi-infinite bodies brought into perfect contact jump at once to a constant interface temperature T_c = (e₁T₁ + e₂T₂)/(e₁ + e₂), where e = √(kρc) is the thermal effusivity. Skin (e ≈ 1,000–1,800) touching steel (e ≈ 13,000) ends up near the steel's temperature, so steel feels cold; touching wood (e ≈ 400) the interface stays near skin temperature. The result holds for short contacts before heat reaches the far side of either body.

Effusivity of body 1 (W·s½/m²·K)15,898
Effusivity of body 2 (W·s½/m²·K)10,356
Contact (interface) temperature502.77°C
Weight of body 1's temperature60.555%

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative skin on steel at 20 C. The inputs, in the units selected above:

InputValue
Body 1 thermal conductivity0.37000 W/(m·K)
Body 1 density1,000.0 kg/m³
Body 1 specific heat3.5000 kJ/(kg·K)
Body 1 temperature34.000 °C
Body 2 thermal conductivity50.000 W/(m·K)
Body 2 density7,850.0 kg/m³
Body 2 specific heat0.46000 kJ/(kg·K)
Body 2 temperature20.000 °C

Applying the formula below gives:

ResultValue
Effusivity of body 1 (W·s½/m²·K)1,138.0
Effusivity of body 2 (W·s½/m²·K)13,437
Contact (interface) temperature21.093 °C
Weight of body 1's temperature7.8078 %

Open this example in the calculator and change any input.

Formula

\(e = \sqrt{k\rho c}, \quad T_c = \frac{e_1T_1 + e_2T_2}{e_1 + e_2}\)

Variables

Symbol Meaning SI unit
\(k_1\) Body 1 thermal conductivity W/(m·K)
\(\rho_1\) Body 1 density kg/m³
\(c_1\) Body 1 specific heat J/(kg·K)
\(T_1\) Body 1 temperature K
\(k_2\) Body 2 thermal conductivity W/(m·K)
\(\rho_2\) Body 2 density kg/m³
\(c_2\) Body 2 specific heat J/(kg·K)
\(T_2\) Body 2 temperature K
\(e_1\) Effusivity of body 1 (W·s½/m²·K) -
\(e_2\) Effusivity of body 2 (W·s½/m²·K) -
\(T_c\) Contact (interface) temperature K
\(w_1\) Weight of body 1's temperature -

Method and standards

Contact temperature.

Where it is used

  • Touch safety of hot and cold surfaces.
  • Die, mould and quench contact temperatures.

Common mistakes

  • Ignoring contact resistance for rough or dirty surfaces.
  • Applying it to long contacts with thin layers.

Assumptions and limits

  • Semi-infinite bodies; perfect contact; constant properties.

References

  • Contact of two semi-infinite solids

Questions and answers

Why does metal feel colder than wood at the same temperature?

Its high effusivity pulls the skin–metal interface close to the metal's temperature.

How long is the result valid?

Until heat penetrates through either body, about L²/α for a layer of thickness L.

What do the defaults represent?

Illustrative skin at 34 °C (k = 0.37, ρ = 1,000, c = 3,500) touching steel at 20 °C.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Incropera, DeWitt, Bergman and Lavine, Fundamentals of Heat and Mass Transfer, 7th ed. (Wiley, 2011)

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.