FireCADCalc

Electrical Conductivity, %IACS and Resistivity at Temperature

Converts a metal's resistivity at 20 °C to conductivity and %IACS, and corrects resistivity and conductivity to another temperature with its coefficient.

Inputs

Examples: Illustrative EC aluminium at 90 CAnnealed copper at 75 CBrass at 20 C

Accepted: 0.1 to 100,000 µΩ·cm
Accepted: -0.01 to 0.02
Accepted: -223.15 to 1,226.8 °C

Results

The International Annealed Copper Standard (1913) defines 100 % IACS as a resistivity of 1/58 Ω·mm²/m (1.7241 µΩ·cm) at 20 °C. Conductivity is the reciprocal of resistivity. Over moderate ranges resistivity varies linearly, ρ_T = ρ₂₀[1 + α₂₀(T − 20 °C)], with α₂₀ = 0.00393/K for annealed copper and 0.00403/K for EC aluminium. Modern pure copper reaches about 101–102 % IACS; aluminium about 61 %.

Conductivity at 20 °C3.5386e+07S/m
Conductivity as % IACS61.008
Resistivity at T3.6232µΩ·cm
Conductivity at T2.7600e+07S/m
Resistance ratio1.2821

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative EC aluminium at 90 C. The inputs, in the units selected above:

InputValue
Resistivity at 20 °C2.8260 µΩ·cm
Temperature coefficient at 20 °C (1/K)0.004030 -
Temperature90.000 °C

Applying the formula below gives:

ResultValue
Conductivity at 20 °C3.5386e+07 S/m
Conductivity as % IACS61.008
Resistivity at T3.6232 µΩ·cm
Conductivity at T2.7600e+07 S/m
Resistance ratio1.2821

Open this example in the calculator and change any input.

Formula

\(\%IACS = 100\frac{1.7241\,\mu\Omega\,\text{cm}}{\rho_{20}}, \quad \rho_T = \rho_{20}[1 + \alpha_{20}(T - 20\,°\text{C})]\)

Variables

Symbol Meaning SI unit
\(\rho_{20}\) Resistivity at 20 °C Ω·m
\(\alpha_{20}\) Temperature coefficient at 20 °C (1/K) -
\(T\) Temperature K
\(\sigma_{20}\) Conductivity at 20 °C S/m
\(\%IACS\) Conductivity as % IACS -
\(\rho_T\) Resistivity at T Ω·m
\(\sigma_T\) Conductivity at T S/m
\(R_T/R_{20}\) Resistance ratio -

Method and standards

IACS conversion.

Where it is used

  • Conductor and busbar specification.
  • Eddy-current conductivity testing of alloys and tempers.

Common mistakes

  • Using the temperature coefficient for a different base temperature.
  • Confusing volume and mass %IACS.

Assumptions and limits

  • Volume conductivity; linear temperature law.

References

  • International Annealed Copper Standard and linear temperature coefficient

Questions and answers

What is 100 % IACS?

The conductivity of the 1913 standard annealed copper, 58 MS/m at 20 °C.

Can %IACS exceed 100?

Yes: modern high-purity copper and silver exceed the old standard.

What do the defaults represent?

An illustrative EC-grade aluminium (2.826 µΩ·cm at 20 °C) at 90 °C.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Callister and Rethwisch, Materials Science and Engineering: An Introduction, 10th ed. (Wiley, 2018)

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.