Worked example
Example: Illustrative chopped fibre 3 mm. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Fibre tensile strength | 3,400.0 MPa |
| Fibre diameter | 10.000 µm |
| Fibre-matrix bond (shear) strength | 40.000 MPa |
| Fibre length | 3.0000 mm |
| Fibre volume fraction | 30.000 % |
| Matrix stress at composite failure | 50.000 MPa |
Applying the formula below gives:
| Result | Value |
|---|---|
| Critical fibre length | 0.42500 mm |
| Length ratio | 7.0588 |
| Composite strength | 982.75 MPa |
| Strength if fibres were continuous | 1,055.0 MPa |
| Strength efficiency | 93.152 % |
Open this example in the calculator and change any input.
Formula
\(l_c = \frac{\sigma_f^*d}{2\tau_c}, \quad \sigma_{cd}^* = \sigma_f^*V_f\left(1 - \frac{l_c}{2l}\right) + \sigma_m'(1 - V_f)\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\sigma_f^*\) | Fibre tensile strength | Pa |
| \(d\) | Fibre diameter | m |
| \(\tau_c\) | Fibre-matrix bond (shear) strength | Pa |
| \(l\) | Fibre length | m |
| \(V_f\) | Fibre volume fraction | - |
| \(\sigma_m'\) | Matrix stress at composite failure | Pa |
| \(l_c\) | Critical fibre length | m |
| \(l/l_c\) | Length ratio | - |
| \(\sigma_{cd}^*\) | Composite strength | Pa |
| \(\sigma_{cl}^*\) | Strength if fibres were continuous | Pa |
| \(\sigma_{cd}^*/\sigma_{cl}^*\) | Strength efficiency | - |
Method and standards
Critical length.
Where it is used
- Short-fibre moulding compounds.
- Choosing chopped fibre length.
Common mistakes
- Using fibre radius instead of diameter.
- Ignoring fibre attrition during moulding.
Assumptions and limits
- Aligned fibres; constant interface shear (Kelly–Tyson).
References
- Shear-lag critical length (Kelly–Tyson)
Questions and answers
Why does fibre length matter?
Fibre ends carry little stress; short fibres pull out before they break, wasting their strength.
How long should chopped fibres be?
Several times the critical length; at 15 l_c the efficiency is above 95 %.
What do the defaults represent?
An illustrative chopped glass or carbon fibre: 3.4 GPa, 10 µm diameter, 40 MPa bond strength, 3 mm long at 30 % volume.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Callister and Rethwisch, Materials Science and Engineering: An Introduction (Wiley)