Worked example
Example: Illustrative steel, HB 3000/10, HV30, HK0.5. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Brinell load | 3,000.0 kgf |
| Brinell ball diameter | 10.000 mm |
| Brinell impression diameter | 4.2000 mm |
| Vickers load | 30.000 kgf |
| Vickers mean diagonal | 0.42000 mm |
| Knoop load | 0.50000 kgf |
| Knoop long diagonal | 0.10500 mm |
Applying the formula below gives:
| Result | Value |
|---|---|
| Brinell hardness | 206.53 |
| Meyer hardness (load/projected area) | 2,123.5 MPa |
| Vickers hardness | 315.37 |
| Knoop hardness | 645.31 |
| Brinell d/D (valid 0.24–0.6) | 0.42000 |
Open this example in the calculator and change any input.
Formula
\(HB = \frac{2F}{\pi D\left(D - \sqrt{D^2 - d^2}\right)}, \quad HV = \frac{1.8544F}{d_V^2}, \quad HK = \frac{14.229F}{L_K^2}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(F_B\) | Brinell load | N |
| \(D\) | Brinell ball diameter | m |
| \(d\) | Brinell impression diameter | m |
| \(F_V\) | Vickers load | N |
| \(d_V\) | Vickers mean diagonal | m |
| \(F_K\) | Knoop load | N |
| \(L_K\) | Knoop long diagonal | m |
| \(HB\) | Brinell hardness | - |
| \(HM\) | Meyer hardness (load/projected area) | Pa |
| \(HV\) | Vickers hardness | - |
| \(HK\) | Knoop hardness | - |
| \(d/D\) | Brinell d/D (valid 0.24–0.6) | - |
Method and standards
Indentation hardness.
Where it is used
- Hardness testing and material checks.
- Heat-treatment verification.
Common mistakes
- Using N instead of kgf.
- Impressions outside the valid d/D range.
Assumptions and limits
- Loads in kgf, lengths in mm inside the formulas.
References
- Indentation hardness definitions
Questions and answers
Why are hardness numbers in kgf/mm²?
The tests were defined that way; the numbers are conventionally quoted without units.
Can I convert HB to HV with these?
Not exactly: conversions depend on the material's work hardening and are empirical.
What do the defaults represent?
An illustrative steel: 3,000 kgf on a 10 mm ball leaving 4.2 mm, HV30 diagonal 0.42 mm, Knoop 500 gf long diagonal 105 µm.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Dieter, Mechanical Metallurgy (McGraw-Hill, 1961), Callister and Rethwisch, Materials Science and Engineering: An Introduction (Wiley)