FireCADCalc

Membrane Bioreactor: Membrane Area and Modules

Membrane area and module count of a membrane bioreactor (MBR) from flow, design flux and the relaxation or backwash time lost, with the net flux and peak check.

Sugar mill and cogenerationDistillery and ethanolRefinery and petrochemicalChemical and fertiliserPulp and paperFood, dairy and textile

Inputs

Examples: 2000 m3/d at 20 LMH, 35 m2 modulesIndustrial 500 m3/d at 12 LMH

Results

Peak flux exceeds the sustainable maximum: add modules or provide peak-flow equalisation.

Typical municipal MBR net flux: 15–25 L/(m²·h) average; industrial wastes often lower. Follow the membrane supplier's design flux.

Membrane area1,750.0m²
Modules (rounded up)70.000
Gross flux while filtering (L/(m²·h))14.118
Net flux at peak flow (L/(m²·h))23.810

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 2000 m3/d at 20 LMH, 35 m2 modules. The inputs, in the units selected above:

InputValue
Average flow2,000.0 m³/d
Peak flow factor1.5000 -
Design net flux at average flow (L/(m²·h))20.000 -
Maximum sustainable peak flux (L/(m²·h))35.000 -
Time lost to relaxation and backwash10.000 %
Membrane area per module35.000 m²

Applying the formula below gives:

ResultValue
Membrane area4,200.0 m²
Modules (rounded up)120.00
Gross flux while filtering (L/(m²·h))22.222
Net flux at peak flow (L/(m²·h))29.762

Open this example in the calculator and change any input.

Formula

\(A_0 = \frac{Q}{J}, \quad n = \left\lceil\frac{A_0}{A_m}\right\rceil, \quad A = n A_m, \quad J_g = \frac{J}{1 - f_{off}}, \quad J_{peak} = \frac{PF\cdot Q}{nA_m}\)

Variables

Symbol Meaning SI unit
\(Q\) Average flow m³/s
\(PF\) Peak flow factor -
\(J\) Design net flux at average flow (L/(m²·h)) -
\(J_{p,max}\) Maximum sustainable peak flux (L/(m²·h)) -
\(f_{off}\) Time lost to relaxation and backwash -
\(A_m\) Membrane area per module m²
\(A\) Membrane area m²
\(n\) Modules (rounded up) -
\(J_g\) Gross flux while filtering (L/(m²·h)) -
\(J_{peak}\) Net flux at peak flow (L/(m²·h)) -

Method and standards

Flux definitions.

Where it is used

  • Effluent reuse plants.
  • Distillery and food MBRs.

Common mistakes

  • Designing at peak flux for average flow.
  • Forgetting cleaning downtime.

Assumptions and limits

  • Net flux design: the area is sized on the net flux J; the downtime share f_off only raises the gross flux while filtering. A is the installed area n A_m (slightly above Q/J).

References

  • Metcalf & Eddy
  • Wastewater Engineering: Treatment and Resource Recovery
  • 5th ed. (McGraw-Hill, 2014)
  • ch. 8 (membrane bioreactors: flux and membrane area)

Questions and answers

What is LMH?

Litres per square metre of membrane per hour: the flux.

Why gross and net flux?

Membranes stop for relaxation or backwash; to deliver the net flow they must filter faster while running.

What do the defaults give?

2,000 m³/d at 20 L/(m²·h): 4,200 m² installed, 120 modules of 35 m².

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.