Spray Dryer Evaporation and Air Flow

Water evaporated, powder produced, dry air flow and outlet humidity of a spray dryer from feed, solids, moisture, air temperatures and heat loss.

Chemical and fertiliserFood, dairy and textile

Inputs

Examples: 5 t/h milk concentrate 48 %Chemical 30 % solidsMilk concentrate, ambient air 35 °C

Results

Air is heated from the ambient temperature entered; the powder's sensible heat is folded into the loss share.

Powder2,487.0kg/h
Water evaporated2,513.0kg/h
Dry air60,953kg/h
Outlet humidity51.228g/kg
Heat to the air in the heater3,036.5kW
Heat per kg water evaporated4.3500MJ/kg

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 5 t/h milk concentrate 48 %. The inputs, in the units selected above:

InputValue
Feed (concentrate)5,000.0 kg/h
Feed solids48.000 %
Powder moisture (wet basis)3.5000 %
Feed temperature50.000 °C
Air inlet200.00 °C
Air outlet90.000 °C
Ambient humidity (kg water per kg dry air)10.000 g/kg
Heat loss share10.000 %
Ambient air temperature (to the heater)25.000 °C

Applying the formula below gives:

ResultValue
Powder2,487.0 kg/h
Water evaporated2,513.0 kg/h
Dry air60,953 kg/h
Outlet humidity51.228 g/kg
Heat to the air in the heater3,036.5 kW
Heat per kg water evaporated4.3500 MJ/kg

Open this example in the calculator and change any input.

Formula

\(P = \frac{F x_F}{1 - w_P}, \quad E = F - P, \quad \dot m_a = \frac{E\,[2501 + 1.88T_2 - 4.187T_F]}{(1 - \varepsilon)(1.006 + 1.88Y_0)(T_1 - T_2)}, \quad Q = \dot m_a(1.006 + 1.88Y_0)(T_1 - T_a)\)

Variables

Symbol Meaning SI unit
\(F\) Feed (concentrate) kg/s
\(x_F\) Feed solids -
\(w_P\) Powder moisture (wet basis) -
\(T_F\) Feed temperature K
\(T_1\) Air inlet K
\(T_2\) Air outlet K
\(Y_0\) Ambient humidity (kg water per kg dry air) kg/kg
\(\varepsilon\) Heat loss share -
\(T_a\) Ambient air temperature (to the heater) K
\(P\) Powder kg/s
\(E\) Water evaporated kg/s
\(\dot m_a\) Dry air kg/s
\(Y_2\) Outlet humidity kg/kg
\(Q\) Heat to the air in the heater W
\(Q/E\) Heat per kg water evaporated J/kg

Method and standards

Solids, water and heat balances on the drying chamber (temperatures in °C in the bracket).

Where it is used

  • Dairy and food powder plants.
  • Chemical spray drying.

Common mistakes

  • Ignoring heat losses.
  • Using the wet-basis feed moisture as solids.

Assumptions and limits

  • Heat loss as a share of the latent load; air heated from the ambient temperature entered (25 °C by default).

References

  • Perry's Chemical Engineers' Handbook
  • 9th ed. (McGraw-Hill, 2019)
  • sec. 12 (spray dryers): mass and heat balances
  • Psychrometric enthalpy basis: 2 501 kJ/kg at 0 °C
  • vapour 1.88 and dry air 1.006 kJ/(kg·K)

Questions and answers

Why is the outlet temperature so important?

It sets the powder moisture; the inlet–outlet difference sets how much air is needed.

What heat use is typical?

4–5 MJ per kg of water for single-stage spray dryers; two-stage with fluid beds is lower.

Why concentrate the feed first?

An evaporator removes water for a fraction of the dryer's energy.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.