FireCADCalc

Drying Time of a Slab by Moisture Diffusion

Falling-rate drying time of a slab drying from both faces under internal diffusion control, from thickness, diffusivity and the moisture contents.

Distillery and ethanolRefinery and petrochemicalChemical and fertiliserPulp and paperFood, dairy and textile

Inputs

Examples: 10 mm slab, 1.0 → 0.15 kg/kgTimber 25 mm, 0.6 → 0.12

Results

Moisture ratio (X − X_e)/(X₀ − X_e)7.6923%
Drying time82.849h

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 10 mm slab, 1.0 → 0.15 kg/kg. The inputs, in the units selected above:

InputValue
Slab thickness (drying from both faces)10.000 mm
Effective moisture diffusivity1.0000e-09 m²/s
Initial moisture, dry basis1.0000 kg/kg
Final moisture, dry basis0.15000 kg/kg
Equilibrium moisture, dry basis0.050000 kg/kg

Applying the formula below gives:

ResultValue
Moisture ratio (X − X_e)/(X₀ − X_e)10.526 %
Drying time5.7451 h

Open this example in the calculator and change any input.

Formula

\(t = \frac{4L^2}{\pi^2D_{eff}}\ln\left(\frac{8}{\pi^2}\frac{X_0 - X_e}{X - X_e}\right)\)

Variables

Symbol Meaning SI unit
\(2L\) Slab thickness (drying from both faces) m
\(D_{eff}\) Effective moisture diffusivity m²/s
\(X_0\) Initial moisture, dry basis kg/kg
\(X\) Final moisture, dry basis kg/kg
\(X_e\) Equilibrium moisture, dry basis kg/kg
\(MR\) Moisture ratio (X − X_e)/(X₀ − X_e) -
\(t\) Drying time s

Method and standards

First-term series solution.

Where it is used

  • Drying of wood, ceramics, foods and pastes.
  • Effect of thickness on dryer time.

Common mistakes

  • Using full thickness as L when both faces dry.
  • Applying it in the constant-rate period.

Assumptions and limits

  • Constant D_eff; no shrinkage.
  • One term of the series: above a moisture ratio of 8/π² ≈ 0.81 it gives no time, and none is shown.

References

  • Perry's Chemical Engineers' Handbook
  • 9th ed. (McGraw-Hill, 2019)
  • sec. 12 (diffusion-controlled falling rate: first term of the series solution of Fick's law)

Questions and answers

Why does thickness matter so much?

Drying time grows with the square of thickness: halving a slab dries it four times as fast.

Where does D_eff come from?

Fitting drying curves; typical values are 10⁻¹¹ to 10⁻⁸ m²/s for foods, wood and clays.

What do the defaults represent?

A 10 mm slab dried from both faces from 1.0 to 0.15 kg/kg with D_eff 10⁻⁹ m²/s.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.