Worked example
Example: 10 mm slab, 1.0 → 0.15 kg/kg. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Slab thickness (drying from both faces) | 10.000 mm |
| Effective moisture diffusivity | 1.0000e-09 m²/s |
| Initial moisture, dry basis | 1.0000 kg/kg |
| Final moisture, dry basis | 0.15000 kg/kg |
| Equilibrium moisture, dry basis | 0.050000 kg/kg |
Applying the formula below gives:
| Result | Value |
|---|---|
| Moisture ratio (X − X_e)/(X₀ − X_e) | 10.526 % |
| Drying time | 5.7451 h |
Open this example in the calculator and change any input.
Formula
\(t = \frac{4L^2}{\pi^2D_{eff}}\ln\left(\frac{8}{\pi^2}\frac{X_0 - X_e}{X - X_e}\right)\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(2L\) | Slab thickness (drying from both faces) | m |
| \(D_{eff}\) | Effective moisture diffusivity | m²/s |
| \(X_0\) | Initial moisture, dry basis | kg/kg |
| \(X\) | Final moisture, dry basis | kg/kg |
| \(X_e\) | Equilibrium moisture, dry basis | kg/kg |
| \(MR\) | Moisture ratio (X − X_e)/(X₀ − X_e) | - |
| \(t\) | Drying time | s |
Method and standards
First-term series solution.
Where it is used
- Drying of wood, ceramics, foods and pastes.
- Effect of thickness on dryer time.
Common mistakes
- Using full thickness as L when both faces dry.
- Applying it in the constant-rate period.
Assumptions and limits
- Constant D_eff; no shrinkage.
- One term of the series: above a moisture ratio of 8/π² ≈ 0.81 it gives no time, and none is shown.
References
- Perry's Chemical Engineers' Handbook
- 9th ed. (McGraw-Hill, 2019)
- sec. 12 (diffusion-controlled falling rate: first term of the series solution of Fick's law)
Questions and answers
Why does thickness matter so much?
Drying time grows with the square of thickness: halving a slab dries it four times as fast.
Where does D_eff come from?
Fitting drying curves; typical values are 10⁻¹¹ to 10⁻⁸ m²/s for foods, wood and clays.
What do the defaults represent?
A 10 mm slab dried from both faces from 1.0 to 0.15 kg/kg with D_eff 10⁻⁹ m²/s.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.