FireCADCalc

Rotary Dryer Volume from Volumetric Heat Transfer

Rotary dryer volume, diameter and length from the heat duty, a volumetric heat transfer coefficient and the log-mean temperature difference between gas and solids.

Sugar mill and cogenerationRefinery and petrochemicalChemical and fertiliserPulp and paperFood, dairy and textile

Inputs

Examples: Co-current, 1.5 MWCounter-current

Per kelvin: W/(m³·K), entered in W/m³ per K in every unit system. Convert Btu/(h·ft³·°F) by × 18.63. Perry's sec. 12 gives Ua from gas mass velocity and diameter.

Results

Log-mean temperature difference121.11K
Dryer volume82.569m³
Diameter2.5973m
Length15.584m

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Co-current, 1.5 MW. The inputs, in the units selected above:

InputValue
Heat to the solids and water1,500.0 kW
Volumetric heat transfer coefficient, W/(m³·K)150.00 W/m³
Gas in400.00 °C
Gas out110.00 °C
Solids in25.000 °C
Solids out90.000 °C
Flow arrangementCo-current
Length to diameter ratio6.0000 -

Applying the formula below gives:

ResultValue
Log-mean temperature difference121.11 K
Dryer volume82.569 m³
Diameter2.5973 m
Length15.584 m

Open this example in the calculator and change any input.

Formula

\(\Delta T_{lm} = \frac{\Delta T_1 - \Delta T_2}{\ln(\Delta T_1/\Delta T_2)}, \quad \text{co-current: } \Delta T_1 = T_{g1} - T_{s1},\ \Delta T_2 = T_{g2} - T_{s2}; \quad \text{counter-current: } \Delta T_1 = T_{g1} - T_{s2},\ \Delta T_2 = T_{g2} - T_{s1}\)

\(V = \frac{Q}{U_a\,\Delta T_{lm}}, \quad D = \sqrt[3]{\frac{4V}{\pi(L/D)}}\)

Variables

Symbol Meaning SI unit
\(Q\) Heat to the solids and water W
\(U_a\) Volumetric heat transfer coefficient, W/(m³·K) W/(m³·K)
\(T_{g1}\) Gas in K
\(T_{g2}\) Gas out K
\(T_{s1}\) Solids in K
\(T_{s2}\) Solids out K
\(\text{flow}\) Flow arrangement -
\(L/D\) Length to diameter ratio -
\(\Delta T_{lm}\) Log-mean temperature difference K
\(V\) Dryer volume m³
\(D\) Diameter m
\(L\) Length m

Method and standards

Volumetric heat transfer design.

Where it is used

  • Rotary dryer and cooler sizing.

Common mistakes

  • Using an area U for U_a.
  • A temperature cross in co-current flow.

Assumptions and limits

  • Uniform U_a; ΔT_lm between gas and solids.
  • U_a is entered in W/(m³·K) in every unit system (no per-degree volumetric quantity exists for automatic conversion); 1 Btu/(h·ft³·°F) = 18.63 W/(m³·K).

References

  • Perry's Chemical Engineers' Handbook
  • 9th ed. (McGraw-Hill, 2019)
  • sec. 12 (rotary dryers): Q = U_a V ΔT_lm

Questions and answers

Where does U_a come from?

Correlations in gas mass velocity and diameter, or vendor and pilot data; typical values are 100–400 W/(m³·K).

Co-current or counter-current?

Co-current suits heat-sensitive products; counter-current gives a larger mean ΔT.

Why an L/D?

Rotary dryers are usually 4–10 diameters long.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.