FireCADCalc

Saturated Liquid Density by the Rackett Equation

Saturated liquid molar volume and density from critical temperature, pressure and the Rackett parameter Z_RA, by the Rackett equation (Perry's sec. 2).

Refinery and petrochemicalChemical and fertiliserPulp and paperFood, dairy and textile

Inputs

Examples: Benzene at 25 °CEthanol at 60 °C (Z_RA 0.2502)

Results

Reduced temperature0.64828
Saturated liquid molar volume62.210cm³/mol
Saturated liquid density740.54kg/m³

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Benzene at 25 °C. The inputs, in the units selected above:

InputValue
Temperature25.000 °C
Critical temperature288.90 °C
Critical pressure48.950 bar
Rackett parameter (or Z_c)0.26980 -
Molar mass78.114 kg/kmol

Applying the formula below gives:

ResultValue
Reduced temperature0.53047
Saturated liquid molar volume89.634 cm³/mol
Saturated liquid density871.48 kg/m³

Open this example in the calculator and change any input.

Formula

\(V_s = \frac{RT_c}{p_c}Z_{RA}^{\,1 + (1 - T_r)^{2/7}}, \quad \rho = \frac{M}{V_s}\)

Variables

Symbol Meaning SI unit
\(T\) Temperature K
\(T_c\) Critical temperature K
\(p_c\) Critical pressure Pa
\(Z_{RA}\) Rackett parameter (or Z_c) -
\(M\) Molar mass kg/kmol
\(T_r\) Reduced temperature -
\(V_s\) Saturated liquid molar volume m³/mol
\(\rho\) Saturated liquid density kg/m³

Method and standards

Rackett equation (Spencer–Danner form).

Where it is used

  • Process simulation checks.
  • Tank and line sizing for organics.

Common mistakes

  • Using Z_c of another compound.
  • Applying above T_c.

Assumptions and limits

  • Saturated liquid; non-polar and slightly polar compounds.

References

  • Perry's Chemical Engineers' Handbook
  • 9th ed. (McGraw-Hill, 2019)
  • sec. 2 (physical properties): Rackett equation with the Spencer–Danner parameter Z_RA

Questions and answers

What is Z_RA?

A fitted compressibility close to Z_c; using Z_RA improves accuracy to about 1 %.

Does it give the density of compressed liquid?

No, saturated liquid only; compressed liquids are slightly denser.

What do the defaults represent?

Benzene: T_c 562.05 K, p_c 48.95 bar, Z_RA 0.2698; about 871 kg/m³ at 25 °C.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.