Worked example
Example: 0.5 m test, 3.0/3.6 h; 2 m bed. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Test bed length | 0.50000 m |
| Test breakthrough time | 3.0000 h |
| Test stoichiometric (mid-front) time | 3.6000 h |
| Design bed length | 2.0000 m |
Applying the formula below gives:
| Result | Value |
|---|---|
| Length of unused bed | 0.083333 m |
| Front velocity | 3.8580e-05 m/s |
| Breakthrough time of the design bed | 13.800 h |
| Bed used at breakthrough | 95.833 % |
Open this example in the calculator and change any input.
Formula
\(LUB = L_t\left(1 - \frac{t_b}{t_s}\right), \quad v_f = \frac{L_t}{t_s}, \quad t_b' = \frac{L - LUB}{v_f}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(L_t\) | Test bed length | m |
| \(t_b\) | Test breakthrough time | s |
| \(t_s\) | Test stoichiometric (mid-front) time | s |
| \(L\) | Design bed length | m |
| \(LUB\) | Length of unused bed | m |
| \(v_f\) | Front velocity | m/s |
| \(t_b'\) | Breakthrough time of the design bed | s |
| \(1 - LUB/L\) | Bed used at breakthrough | - |
Method and standards
Constant-pattern LUB method.
Where it is used
- Activated carbon, molecular sieve and ion-exchange bed design.
Common mistakes
- Scaling with a different superficial velocity.
- Using the 50 % point for an asymmetric curve.
Assumptions and limits
- Constant-pattern front; same superficial velocity, particle size and temperature as the test. There is no input for a velocity change: scale the test to the design velocity before using it.
References
- Perry's Chemical Engineers' Handbook
- 9th ed. (McGraw-Hill, 2019)
- sec. 16 (adsorption): length of unused bed (LUB) scale-up for a constant-pattern front
Questions and answers
What is the stoichiometric time?
The time at which the front's midpoint (or the time equivalent of the area above the curve) reaches the bed end.
Why does the LUB stay constant?
With a favourable isotherm the mass-transfer zone keeps a constant shape as it moves.
When does it fail?
At different velocities, particle sizes or temperatures from the test.