FireCADCalc

Gas Mixture Viscosity by Wilke's Rule (Binary)

Viscosity of a binary gas mixture from the pure-gas viscosities, molar masses and mole fractions by Wilke's semi-empirical mixing rule (Perry's sec. 2).

Thermal power plantRefinery and petrochemicalChemical and fertiliserPulp and paperFood, dairy and textile

Inputs

Examples: N2–CO2 50/50 at 300 KH2–N2 30/70

Results

Interaction parameter Φ₁₂1.3682
Interaction parameter Φ₂₁0.72743
Mixture viscosity0.015942cP

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: N2–CO2 50/50 at 300 K. The inputs, in the units selected above:

InputValue
Mole fraction of gas 150.000 %
Viscosity of gas 10.017600 cP
Viscosity of gas 20.014700 cP
Molar mass of gas 128.014 kg/kmol
Molar mass of gas 244.009 kg/kmol

Applying the formula below gives:

ResultValue
Interaction parameter Φ₁₂1.3682
Interaction parameter Φ₂₁0.72743
Mixture viscosity0.015942 cP

Open this example in the calculator and change any input.

Formula

\(\mu_m = \sum_i\frac{y_i\mu_i}{\sum_j y_j\Phi_{ij}}, \quad \Phi_{ij} = \frac{\left[1 + (\mu_i/\mu_j)^{1/2}(M_j/M_i)^{1/4}\right]^2}{\sqrt{8(1 + M_i/M_j)}}\)

Variables

Symbol Meaning SI unit
\(y_1\) Mole fraction of gas 1 -
\(\mu_1\) Viscosity of gas 1 Pa·s
\(\mu_2\) Viscosity of gas 2 Pa·s
\(M_1\) Molar mass of gas 1 kg/kmol
\(M_2\) Molar mass of gas 2 kg/kmol
\(\Phi_{12}\) Interaction parameter Φ₁₂ -
\(\Phi_{21}\) Interaction parameter Φ₂₁ -
\(\mu_m\) Mixture viscosity Pa·s

Method and standards

Wilke's rule (Φ_ii = 1).

Where it is used

  • Flue gas and process gas property estimates.

Common mistakes

  • Using at high pressure.
  • Mixing mass and mole fractions.

Assumptions and limits

  • Low-pressure gases.

References

  • Perry's Chemical Engineers' Handbook
  • 9th ed. (McGraw-Hill, 2019)
  • sec. 2 (transport properties): Wilke's mixing rule for low-pressure gas mixtures

Questions and answers

Why not average by mole fraction?

Light, viscous molecules such as hydrogen distort a simple average; Wilke's rule corrects for it.

How accurate is it?

About 1–2 % for non-polar gases at low pressure.

What do the defaults represent?

Nitrogen and CO₂ at about 300 K.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.