FireCADCalc

Falling-Rate Drying Time (Linear Rate)

Drying time in the falling-rate period when the rate falls linearly from the critical moisture to zero at equilibrium moisture (Perry's sec. 12).

Refinery and petrochemicalChemical and fertiliserPulp and paperFood, dairy and textile

Inputs

Examples: To 5 % from 30 %To 2 %

Results

Falling-rate drying time16.537h
Rate at the end0.073846kg/(m²·h)

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: To 5 % from 30 %. The inputs, in the units selected above:

InputValue
Dry solids500.00 kg
Drying surface25.000 m²
Critical moisture (dry basis)0.30000 kg/kg
Final moisture (dry basis)0.050000 kg/kg
Equilibrium moisture (dry basis)0.020000 kg/kg
Constant drying rate1.8000 kg/(m²·h)

Applying the formula below gives:

ResultValue
Falling-rate drying time6.9490 h
Rate at the end0.19286 kg/(m²·h)

Open this example in the calculator and change any input.

Formula

\(t_f = \frac{m_s(X_c - X^*)}{A N_c}\ln\frac{X_c - X^*}{X_2 - X^*}\)

Variables

Symbol Meaning SI unit
\(m_s\) Dry solids kg
\(A\) Drying surface m²
\(X_c\) Critical moisture (dry basis) kg/kg
\(X_2\) Final moisture (dry basis) kg/kg
\(X^*\) Equilibrium moisture (dry basis) kg/kg
\(N_c\) Constant drying rate kg/(m²·s)
\(t_f\) Falling-rate drying time s
\(N_2\) Rate at the end kg/(m²·s)

Method and standards

Integration of a rate linear in free moisture.

Where it is used

  • Dryer sizing.
  • Estimating time to final moisture.

Common mistakes

  • Using X₂ below X*.
  • Mixing wet and dry bases.

Assumptions and limits

  • Linear falling rate.

References

  • Perry's Chemical Engineers' Handbook
  • 9th ed. (McGraw-Hill, 2019)
  • sec. 12 (drying): falling-rate period with rate proportional to free moisture

Questions and answers

Why does the rate fall?

Moisture must move from inside the solid to the surface, which slows as the solid dries.

Why can't I reach X*?

The time grows logarithmically and becomes infinite at the equilibrium moisture.

Is the linear rate exact?

It is the simplest model; measured drying curves are better.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.