FireCADCalc

Blend Time in a Turbulent Stirred Tank

Time to blend a stirred tank to 95 % uniformity in turbulent flow from impeller power number, speed and diameter ratio (Grenville), with power per volume.

Distillery and ethanolRefinery and petrochemicalChemical and fertiliserPulp and paperFood, dairy and textile

Inputs

Examples: 3 m tank, 1 m PBT at 90 rpmRushton D/T 0.33 at 120 rpm

Results

Grenville's correlation applies to H/T about 1 and fully turbulent flow; for taller tanks use multiple impellers.

Impeller Reynolds number1,500,000
Blend time to 95 %28.811s
Power per volume (H = T)0.20213kW/m³

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 3 m tank, 1 m PBT at 90 rpm. The inputs, in the units selected above:

InputValue
Impeller power number1.2700 -
Impeller speed90.000 rpm
Impeller diameter1.0000 m
Tank diameter3.0000 m
Liquid density1,000.0 kg/m³
Liquid viscosity1.0000 cP

Applying the formula below gives:

ResultValue
Impeller Reynolds number1,500,000
Blend time to 95 %28.811 s
Power per volume (H = T)0.20213 kW/m³

Open this example in the calculator and change any input.

Formula

\(\theta_{95} = \frac{5.20}{N\,N_p^{1/3}}\left(\frac{T}{D}\right)^2, \quad Re = \frac{\rho ND^2}{\mu}, \quad \frac{P}{V} = \frac{N_p\rho N^3D^5}{\pi T^3/4}\)

Variables

Symbol Meaning SI unit
\(N_p\) Impeller power number -
\(N\) Impeller speed 1/s
\(D\) Impeller diameter m
\(T\) Tank diameter m
\(\rho\) Liquid density kg/m³
\(\mu\) Liquid viscosity Pa·s
\(Re\) Impeller Reynolds number -
\(\theta_{95}\) Blend time to 95 % s
\(P/V\) Power per volume (H = T) W/m³

Method and standards

Grenville's correlation.

Where it is used

  • Additive dosing and neutralisation tanks.
  • Batch blending specifications.

Common mistakes

  • Applying it in laminar or transitional flow.
  • Using it for tall tanks with one impeller.

Assumptions and limits

  • H ≈ T (the volume for P/V is a cylinder with H = T); baffled; turbulent. The power number is taken as constant, which holds only in turbulent flow; below Re 10 000 the time is shown with a warning and is too short.
  • Grenville fitted the correlation over a limited range of D/T; check yours against the Handbook of Industrial Mixing.

References

  • Grenville (1992) correlation
  • θ₉₅N = 5.20 N_p^(−1/3)(T/D)²
  • in Paul
  • Atiemo-Obeng and Kresta
  • Handbook of Industrial Mixing (Wiley, 2004)
  • ch. 9

Questions and answers

Why does a bigger impeller blend faster?

Blend time falls with (D/T)²: a large, slow impeller circulates the whole tank more effectively than a small fast one.

Is blend time the same for all impellers at equal power?

Nearly so in turbulent flow: at equal power per volume and D/T, blend time is almost independent of impeller type.

What do the defaults represent?

A 3 m tank stirred by a 1 m pitched-blade turbine at 90 rpm in water.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.