RO Recovery, Reject Flow and Concentration

Recovery, reject flow, permeate and reject TDS and concentration factor of a reverse osmosis (RO) plant from feed and permeate flows, feed TDS and salt rejection.

Thermal power plantProcess steam and utilitiesSugar mill and cogenerationChemical and fertiliserWater treatment plant

Inputs

Examples: Brackish RO: 20 m³/h feed, 15 m³/h permeate, 1500 mg/L, 98 %10 m³/h, 7 m³/h, 800 mg/L, 97 %Second pass: 15 m³/h, 13.5 m³/h, 30 mg/L, 95 %

Results

Permeate TDS is on the feed concentration (optimistic). On the average of feed and reject, 1705 mg/L, it would be about 51.2 mg/L; membrane software uses a basis of that kind.

Recovery70.000%
Reject flow3.0000m³/h
Permeate TDS24.000mg/L
Reject TDS2,610.7mg/L
Concentration factor of the reject3.2633

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Brackish RO: 20 m³/h feed, 15 m³/h permeate, 1500 mg/L, 98 %. The inputs, in the units selected above:

InputValue
Feed flow20.000 m³/h
Permeate flow15.000 m³/h
Feed TDS1,500.0 mg/L
Salt rejection98.000 %

Applying the formula below gives:

ResultValue
Recovery75.000 %
Reject flow5.0000 m³/h
Permeate TDS30.000 mg/L
Reject TDS5,910.0 mg/L
Concentration factor of the reject3.9400

Open this example in the calculator and change any input.

Formula

\(r = \frac{Q_p}{Q_f} \qquad Q_r = Q_f - Q_p \qquad C_p = (1 - R)\,C_f \qquad C_r = \frac{Q_f\,C_f - Q_p\,C_p}{Q_r} \qquad CF = \frac{C_r}{C_f}\)

Variables

Symbol Meaning SI unit
\(Q_f\) feed flow m³/s
\(Q_p\) permeate flow m³/s
\(C_f\) feed TDS kg/m³
\(R\) salt rejection –
\(r\) recovery –
\(Q_r\) reject flow m³/s
\(C_p\) permeate TDS kg/m³
\(C_r\) reject TDS kg/m³
\(CF\) concentration factor –

Method and standards

Water and salt balances across the RO; permeate TDS from the salt rejection on the feed concentration (a simple, slightly optimistic basis; membrane software uses the average feed-concentrate concentration).

Where it is used

  • First sizing of RO plants for boiler make-up.
  • Disposal planning for the reject stream.
  • Monitoring recovery and salt passage.

Common mistakes

  • Taking the rejection on the feed when the membrane data quote it on the average concentration.
  • Forgetting the reject volume in the raw water demand.
  • Pushing recovery without checking scaling.

Assumptions and limits

  • Steady state; rejection constant; no concentration polarisation.
  • At high recovery the permeate TDS on the feed basis can be several times too low; the note gives the value on the average feed-reject concentration.
  • The 85 % recovery warning is a screening level, not a sourced limit.

References

  • Reverse-osmosis mass balance (water and salt)

Questions and answers

What is RO recovery?

Permeate flow over feed flow. 15 m³/h of permeate from 20 m³/h of feed is 75 % recovery, leaving 5 m³/h of reject.

How salty is the reject?

With 1500 mg/L feed and 98 % rejection, the permeate has 30 mg/L and the reject 5910 mg/L, a concentration factor of 3.9.

Why not run at higher recovery?

The reject concentrates and scales the last membranes. The membrane maker's design software sets the safe recovery for your water and antiscalant.

Method and article reviewed by FireCAD engineering on 11 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.