Oxygen Scavenger Dose (Sodium Sulphite, Hydrazine)

Sodium sulphite or hydrazine dose for boiler feedwater from the dissolved oxygen, feed flow and excess residual, from the reaction stoichiometry.

Thermal power plantProcess steam and utilitiesSugar mill and cogenerationChemical and fertiliserBoilerWater treatment plantDeaerator and feedwater system

Inputs

Examples: 10 t/h feed without deaerator, 7 ppm O2, sulphite, 20 ppm excess50 t/h, 0.02 ppm O2 after deaerator, hydrazine, 0.03 ppm excess, 15 % solution5 t/h, 0.5 ppm, sulphite, 30 ppm excess, 95 % powder

A feedwater concentration, set by your water-treatment programme. Sulphite is controlled as a residual in the boiler water, which the feedwater excess builds up to through the cycles of concentration less blowdown.

Results

The excess is a feedwater concentration. A boiler-water residual is reached by concentration over the cycles, less what blowdown removes; set the feedwater excess from the residual your programme specifies.

Dose in the feedwater (active)0.050030ppm
Active chemical feed0.002502kg/h
Product feed as supplied0.016677kg/h
Stoichiometric ratio, kg chemical per kg O₂1.0015kg/kg

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 10 t/h feed without deaerator, 7 ppm O2, sulphite, 20 ppm excess. The inputs, in the units selected above:

InputValue
Feedwater flow10,000 kg/h
Dissolved oxygen in the feedwater7.0000 ppm
ScavengerSodium sulphite (Na₂SO₃)
Excess dose kept above the oxygen demand20.000 ppm
Active content of the product as dosed100.00 %

Applying the formula below gives:

ResultValue
Dose in the feedwater (active)75.145 ppm
Active chemical feed0.75145 kg/h
Product feed as supplied0.75145 kg/h
Stoichiometric ratio, kg chemical per kg O₂7.8778 kg/kg

Open this example in the calculator and change any input.

Formula

\(r_{sulphite} = \frac{2\,M_{Na_2SO_3}}{M_{O_2}} \qquad r_{hydrazine} = \frac{M_{N_2H_4}}{M_{O_2}}\)

\(D = O_2\,r + e \qquad \dot m_c = \dot m_{fw}\,D \qquad \dot m_p = \frac{\dot m_c}{w}\)

Variables

Symbol Meaning SI unit
\(\dot m_{fw}\) feedwater flow kg/s
\(O_2\) dissolved oxygen, mass fraction –
\(\text{chem}\) sodium sulphite or hydrazine –
\(e\) excess dose above the oxygen demand –
\(w\) active content of the product –
\(D\) dose in the feedwater –
\(\dot m_c\) active chemical feed kg/s
\(\dot m_p\) product feed kg/s
\(r\) stoichiometric ratio kg/kg
\(M\) molar masses from IUPAC atomic weights kg/kmol

Method and standards

Stoichiometry of the scavenging reactions with molar masses from IUPAC 2013 atomic weights.

Where it is used

  • Dosing pumps and chemical budgets for boilers.
  • Comparing chemical scavenging with feed tank heating or a deaerator.
  • Checking a supplier's recommended dose.

Common mistakes

  • Dosing several ppm of oxygen chemically instead of deaerating first.
  • Using the product rate as active chemical (solutions are often 10–40 %).
  • Overdosing sulphite in high-pressure boilers, where it decomposes.

Assumptions and limits

  • Complete reaction; oxygen measured where the dose is injected.
  • The excess is a feedwater concentration. The boiler-water residual that programmes control depends on the cycles of concentration and blowdown, which are not modelled here.
  • Sulphite decomposes in high-pressure boilers; there is no pressure input, so the page always reminds you of this for sulphite.

References

  • Reaction stoichiometry (2 Na2SO3 + O2 → 2 Na2SO4; N2H4 + O2 → N2 + 2 H2O)
  • IUPAC 2013 atomic weights

Questions and answers

How much sodium sulphite removes 1 ppm of oxygen?

7.88 ppm of pure sodium sulphite by the reaction 2 Na₂SO₃ + O₂ → 2 Na₂SO₄. A 10 t/h boiler without a deaerator, with 7 ppm oxygen and a 20 ppm excess, needs 75 ppm, about 0.75 kg/h.

And hydrazine?

About 1 ppm per ppm of oxygen (N₂H₄ + O₂ → N₂ + 2 H₂O). It adds no solids, so high-pressure boilers use it or its safer replacements; it is toxic and handled under strict rules.

Why the excess?

The reaction must finish in the feed line and the boiler; programmes keep a residual of sulphite in the boiler water. Your water-treatment supplier sets it.

Method and article reviewed by FireCAD engineering on 11 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.