Worked example
Example: Juice leak by conductivity. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Tracer in clean condensate | 2.0000 - |
| Tracer in the contaminant | 4,000.0 - |
| Tracer in the mixed condensate | 12.000 - |
| Condensate returned | 50.000 t/h |
Applying the formula below gives:
| Result | Value |
|---|---|
| Contaminant share of the condensate | 2,501.3 ppm |
| Contaminant flow | 125.06 kg/h |
Open this example in the calculator and change any input.
Formula
\(f = \frac{\kappa_m - \kappa_c}{\kappa_x - \kappa_c}, \quad \dot m_x = f\,\dot m\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\kappa_c\) | Tracer in clean condensate | - |
| \(\kappa_x\) | Tracer in the contaminant | - |
| \(\kappa_m\) | Tracer in the mixed condensate | - |
| \(\dot m\) | Condensate returned | kg/s |
| \(f\) | Contaminant share of the condensate | - |
| \(\dot m_x\) | Contaminant flow | kg/s |
Method and standards
Tracer balance.
Where it is used
- Sugar mill condensate monitoring.
- Condenser leak detection.
Common mistakes
- Conductivity of a different temperature basis.
Assumptions and limits
- Linear mixing of the tracer. Sodium and TOC mix linearly by mass; conductivity is only approximately additive and depends on temperature, so use temperature-compensated readings and treat the share as an estimate.
- The mixed reading must lie between the clean and contaminant readings; otherwise the inputs are rejected.
References
- Two-component tracer mass balance
Questions and answers
Why does sugar in condensate matter?
Sugar breaks down in the boiler to organic acids, dropping pH and foaming.
Which tracer?
Sodium for cooling-water leaks, TOC or a sugar test for juice, conductivity as a first alarm.
What then?
Dump the condensate until the leak is found; use the boiler upset calculator to plan recovery.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.