FireCADCalc

Neutralising Amine Dose for Condensate

Neutralising amine (morpholine, cyclohexylamine, ammonia) feed to neutralise the CO₂ in steam and keep a free amine residual, from steam flow and CO₂ content.

Thermal power plantProcess steam and utilitiesSugar mill and cogenerationChemical and fertiliserBoilerWater treatment plant

Inputs

Examples: 10 t/h steam, 10 ppm CO2, morpholine, 5 ppm residual, 40 % solution30 t/h, 5 ppm, cyclohexylamine, 2 ppm, 25 %100 t/h, 1 ppm, ammonia, 0.5 ppm, 25 %

Results

The amine splits between steam and condensate by its distribution ratio: a far end of the system may need a higher dose than this average.

Dose in the steam (active)13.268ppm
Active amine feed0.39803kg/h
Product feed1.5921kg/h
Amine to neutralise 1 kg CO₂ (to bicarbonate)2.2536kg/kg

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 10 t/h steam, 10 ppm CO2, morpholine, 5 ppm residual, 40 % solution. The inputs, in the units selected above:

InputValue
Steam flow10,000 kg/h
CO₂ in the steam10.000 ppm
AmineMorpholine
Free amine residual to keep in the steam5.0000 ppm
Amine content of the product40.000 %

Applying the formula below gives:

ResultValue
Dose in the steam (active)24.796 ppm
Active amine feed0.24796 kg/h
Product feed0.61991 kg/h
Amine to neutralise 1 kg CO₂ (to bicarbonate)1.9796 kg/kg

Open this example in the calculator and change any input.

Formula

\(r = \frac{M_{amine}}{M_{CO_2}} \qquad D = CO_2\,r + R \qquad \dot m_a = \dot m_s\,D \qquad \dot m_p = \frac{\dot m_a}{w}\)

Variables

Symbol Meaning SI unit
\(\dot m_s\) steam flow kg/s
\(CO_2\) CO₂ in steam, mass fraction –
\(\text{amine}\) morpholine, cyclohexylamine or ammonia –
\(R\) free amine residual –
\(w\) amine content of the product –
\(D\) dose in the steam –
\(\dot m_a\) active amine feed kg/s
\(\dot m_p\) product feed kg/s
\(r\) amine per kg CO₂ kg/kg
\(M\) molar masses from IUPAC atomic weights kg/kmol

Method and standards

One mole of amine neutralises one mole of CO₂ as bicarbonate; molar masses of morpholine (C₄H₉NO), cyclohexylamine (C₆H₁₃N) and ammonia from IUPAC 2013 atomic weights.

Where it is used

  • Condensate corrosion control in process steam plants.
  • Estimating amine budgets.
  • Checking a supplier's dose recommendation.

Common mistakes

  • Dosing amine for oxygen corrosion, which it does not stop.
  • Using the product rate as active amine.
  • Ignoring food-contact rules where steam touches product.

Assumptions and limits

  • CO₂ given as measured in the steam; bicarbonate neutralisation; distribution between phases not modelled.
  • Neutralising to bicarbonate is the minimum. Reaching a target condensate pH (often 8.5–9.2) usually needs more amine than the stoichiometric amount; the free residual you enter is where that margin goes.

References

  • Neutralisation stoichiometry (amine + CO2 + H2O → amine bicarbonate, 1:1)
  • IUPAC 2013 atomic weights

Questions and answers

How much amine neutralises the CO₂ in steam?

For morpholine, 1.98 kg per kg of CO₂ (to bicarbonate). 10 t/h of steam with 10 ppm CO₂ and a 5 ppm free residual needs 24.8 ppm, 0.25 kg/h of morpholine or 0.62 kg/h of a 40 % product.

Why does the far end of the system need more?

Each amine splits between steam and condensate by its distribution ratio; a low-ratio amine protects the first condensate, a high-ratio one travels further. Blends cover both.

Where does the CO₂ come from?

From the breakdown of bicarbonate and carbonate alkalinity in the boiler water. Dealkalising the make-up reduces it at source.

Method and article reviewed by FireCAD engineering on 11 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.