Economiser Heat Balance (Water Outlet Temperature)

Economiser duty and feedwater outlet temperature from the flue gas flow and temperatures and the water flow, with the approach to saturation (IAPWS-IF97).

Thermal power plantProcess steam and utilitiesSugar mill and cogenerationPulp and paperFood, dairy and textileIAPWS-IF97 (water and steam)BoilerEconomiser and air preheaterBoiler operation engineer (BOE) examinations

Inputs

Examples: Coal boiler: gas 37 kg/s 350 to 180 °C, water 14.2 kg/s at 70 bar(a) from 150 °CPackage boiler: gas 5 kg/s 260 to 140 °C, water 4 kg/s at 12 bar(a) from 105 °CHRSG economiser: gas 120 kg/s 230 to 110 °C, water 25 kg/s at 90 bar(a) from 60 °C

Between the two gas temperatures; the gas properties calculator gives it.

Results

Feedwater temperature out204.37°C
Economiser duty15,408kW
Approach to saturation (steaming margin)98.973K
Feedwater temperature rise144.37K
Feedwater enthalpy out875.01kJ/kg

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Coal boiler: gas 37 kg/s 350 to 180 °C, water 14.2 kg/s at 70 bar(a) from 150 °C. The inputs, in the units selected above:

InputValue
Flue gas flow133,200 kg/h
Mean specific heat of the flue gas1.0800 kJ/(kg·K)
Gas temperature in350.00 °C
Gas temperature out180.00 °C
Feedwater flow51,120 kg/h
Feedwater pressure (absolute)70.000 bar
Feedwater temperature in150.00 °C

Applying the formula below gives:

ResultValue
Feedwater temperature out255.98 °C
Economiser duty6,793.2 kW
Approach to saturation (steaming margin)29.851 K
Feedwater temperature rise105.98 K
Feedwater enthalpy out1,114.7 kJ/kg

Open this example in the calculator and change any input.

Formula

\(\dot Q = \dot m_g\,c_{p,g}\,(T_{g,1} - T_{g,2}) \qquad h_{w,2} = h_{w,1} + \frac{\dot Q}{\dot m_w} \qquad T_{w,2} = T(p_w, h_{w,2})\)

\(\Delta T_w = T_{w,2} - T_{w,1} \qquad \Delta T_{sat} = T_{sat}(p_w) - T_{w,2}\)

Variables

Symbol Meaning SI unit
\(\dot m_g\) flue gas flow kg/s
\(c_{p,g}\) mean specific heat of flue gas J/(kg·K)
\(T_{g,1}\) gas temperature in K
\(T_{g,2}\) gas temperature out K
\(\dot m_w\) feedwater flow kg/s
\(p_w\) feedwater pressure, absolute Pa
\(T_{w,1}\) feedwater temperature in K
\(T_{w,2}\) feedwater temperature out K
\(\dot Q\) economiser duty W
\(\Delta T_{sat}\) approach to saturation K
\(\Delta T_w\) feedwater temperature rise K
\(h_{w,1}\) feedwater enthalpy in J/kg
\(h_{w,2}\) feedwater enthalpy out J/kg
\(T_{sat}\) saturation temperature at feedwater pressure K

Method and standards

A first-law balance across the economiser: gas-side duty from flow, mean specific heat and temperature drop; water-side outlet enthalpy and temperature by FireCAD's IAPWS-IF97 (backward equation T(p,h)). Heat loss from the economiser casing is neglected.

Where it is used

  • Checking an economiser's performance from plant readings.
  • Sizing a new or added economiser at the proposal stage, before the surface area is found with the LMTD.
  • Checking that the water stays below saturation at part load.
  • Heat recovery steam generators and waste heat boilers, for the economiser section.

Common mistakes

  • Using the specific heat at one temperature instead of the mean over the range.
  • Ignoring air leakage: a measured gas outlet temperature with leakage air mixed in is too low.
  • Forgetting the feedwater recirculation or bypass, so the water flow is not the steam flow.
  • Using gauge pressure as absolute.

Assumptions and limits

  • No heat loss from the casing; steady flow.
  • Water side single-phase; a warning is given if it reaches saturation, and for a temperature cross at either end.
  • The water-side pressure drop is neglected: the outlet saturation temperature is taken at the inlet pressure, which slightly overstates the approach.
  • At or above the critical pressure (220.64 bar) there is no saturation temperature, so the approach is not shown.

References

  • IAPWS R7-97(2012) IF97
  • first law heat balance

Questions and answers

How do I find the economiser water outlet temperature?

The heat the gas gives up goes into the water. 37 kg/s of gas cooling from 350 to 180 °C gives 6.79 MW; 14.2 kg/s of water at 70 bar(a) entering at 150 °C leaves at 256 °C, 30 K below saturation.

What approach to saturation should an economiser have?

Non-steaming economisers are usually designed to leave the water 20–40 K below saturation at full load, so that it does not steam at part load or in upsets. A steaming economiser is designed for it on purpose.

Which gas specific heat?

The mean value between the two gas temperatures, about 1.05–1.10 kJ/(kg·K) for coal flue gas. The gas properties calculator gives it from the gas analysis.

Method and article reviewed by FireCAD engineering on 10 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.