Stack Gas Reheat after a Wet Scrubber

Heat to reheat saturated flue gas above its dew point and the steam it takes at a heating pressure (IF97), against stack condensation and plume.

Thermal power plantProcess steam and utilitiesSugar mill and cogenerationDistillery and ethanolIAPWS-IF97 (water and steam)Stack and chimney

Inputs

Examples: +20 K with 6 bar steam+30 K

Absolute: add the atmospheric pressure (about 1.013 bar) to a header gauge reading.

Results

A gas–gas heater using the hot inlet gas avoids steam but adds leakage and corrosion risk.

Reheat duty672.22kW
Steam condensed1,160.3kg/h

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: +20 K with 6 bar steam. The inputs, in the units selected above:

InputValue
Wet flue gas flow110.00 t/h
Wet gas specific heat1.1000 kJ/(kg·K)
Reheat temperature rise20.000 K
Heating steam pressure (absolute)6.0000 bar

Applying the formula below gives:

ResultValue
Reheat duty672.22 kW
Steam condensed1,160.3 kg/h

Open this example in the calculator and change any input.

Formula

\(\dot Q = \dot m_g c_p \Delta T, \quad \dot m_s = \frac{\dot Q}{h_{fg}(p_s)}\)

Variables

Symbol Meaning SI unit
\(\dot m_g\) Wet flue gas flow kg/s
\(c_p\) Wet gas specific heat J/(kg·K)
\(\Delta T\) Reheat temperature rise K
\(p_s\) Heating steam pressure (absolute) Pa
\(\dot Q\) Reheat duty W
\(\dot m_s\) Steam condensed kg/s

Method and standards

Energy balance on the gas with a mean wet-gas specific heat; the steam condensed is the duty over the latent heat at the heating pressure (IAPWS-IF97).

Where it is used

  • Scrubber stack design.

Common mistakes

  • Using dry gas flow.

Assumptions and limits

  • No droplets carried. Gas leaving a wet scrubber usually carries droplets that must be evaporated before its temperature rises; that heat can be large and is not included, so allow for it or use the mist eliminator maker's carry-over.
  • Dry saturated heating steam in, saturated condensate out, no heater loss: superheat in the steam or subcooled condensate lowers the steam needed.
  • The heating steam pressure is absolute.

References

  • Energy balance; latent heat from IAPWS-IF97

Questions and answers

Why reheat?

Saturated gas condenses in the stack, corroding it and raining out droplets; reheat also helps buoyancy.

How much?

A rise of 15–30 K above saturation is common.

Alternatives?

Wet stack designs with liners and drains, or a gas–gas heater.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.