FireCADCalc

SNCR Urea Dose for NOx Reduction

Urea and urea solution for a selective non-catalytic reduction (SNCR) system from the NOx load and the normalised stoichiometric ratio, with the NOx removed and the reagent utilisation.

Thermal power plantProcess steam and utilitiesSugar mill and cogenerationDistillery and ethanolBoilerStack and chimney

Inputs

Examples: 100 000 Nm3/h, 400 mg/Nm3Bagasse boiler

Moles of NH₃ equivalent per mole of inlet NOx; 1 mol urea = 2 NH₃.
About 1110 kg/m³ for 40 % urea at 20 °C; it falls with strength (about 1090 kg/m³ at 32.5 %). Enter the value for your solution.

Results

SNCR works only in a temperature window (roughly 850–1100 °C for urea): outside it urea slips as ammonia or burns to NOx.

NOx at the inlet (as NO₂)75.000kg/h
NOx removed (as NO₂)26.250kg/h
Urea (100 %)97.907kg/h
Urea solution276.38L/h
Reagent utilisation η/NSR17.500%

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 100 000 Nm3/h, 400 mg/Nm3. The inputs, in the units selected above:

InputValue
Flue gas flow (dry, normal)100,000 Nm³/h
NOx at the inlet (as NO₂, dry)400.00 mg/Nm³
NOx reduction wanted40.000 %
Normalised stoichiometric ratio1.8000 -
Urea strength of the solution40.000 %
Solution density1,110.0 kg/m³

Applying the formula below gives:

ResultValue
NOx at the inlet (as NO₂)40.000 kg/h
NOx removed (as NO₂)16.000 kg/h
Urea (100 %)46.995 kg/h
Urea solution105.85 L/h
Reagent utilisation η/NSR22.222 %

Open this example in the calculator and change any input.

Formula

\(\dot n_{NO_x} = \frac{\dot V_n c_{NO_x}}{M_{NO_2}}, \quad \dot m_u = \dot n_{NO_x}\frac{NSR}{2}M_{urea}, \quad \dot V_s = \frac{\dot m_u}{w\rho_s}\)

Variables

Symbol Meaning SI unit
\(\dot V_n\) Flue gas flow (dry, normal) Nm³/s
\(c_{NO_x}\) NOx at the inlet (as NO₂, dry) kg/m³
\(\eta\) NOx reduction wanted -
\(NSR\) Normalised stoichiometric ratio -
\(w\) Urea strength of the solution -
\(\rho_s\) Solution density kg/m³
\(\dot m_{NO_x}\) NOx at the inlet (as NO₂) kg/s
\(\Delta\dot m_{NO_x}\) NOx removed (as NO₂) kg/s
\(\dot m_u\) Urea (100 %) kg/s
\(\dot V_s\) Urea solution m³/s
\(u\) Reagent utilisation η/NSR -

Method and standards

Stoichiometry: the urea dose follows from the inlet NOx (as NO₂) and the NSR, at two NH₃ equivalents per mole of urea. The reduction wanted does not change the dose; it gives the NOx removed and the utilisation η/NSR, and a warning appears when that would exceed 100 %.

Where it is used

  • SNCR system sizing.
  • Reagent budgets.

Common mistakes

  • NOx as NO instead of NO₂.
  • Wet gas flow with dry concentration.

Assumptions and limits

  • Dry, normal basis throughout.
  • The solution density is not linked to the strength: change it when you change the strength.

References

  • Stoichiometry CO(NH₂)₂ + 2 NO + ½ O₂ → 2 N₂ + CO₂ + 2 H₂O (one mole of urea per two of NO); NSR as NH₃ equivalents per mole of NOx

Questions and answers

What is NSR?

Moles of reducing agent, as NH₃ equivalents, per mole of NOx entering; urea counts double.

Why is NSR above the reduction?

SNCR utilisation is poor: reagent is lost to oxidation and slip, so NSR of 1.5–2.5 is common.

Urea or ammonia?

Urea is safer to store; aqueous ammonia gives a slightly different temperature window.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.