FireCADCalc

NOx from Fuel Nitrogen (Fuel NOx)

Fuel NOx formed from the nitrogen in a fuel, as NO₂ mass and concentration in the flue gas, for a conversion share of fuel nitrogen to NO.

Thermal power plantProcess steam and utilitiesSugar mill and cogenerationDistillery and ethanolStack and chimney

Inputs

Examples: 1 % N, 25 % conversionHusk

Results

Thermal NOx from air nitrogen comes on top; staging and low excess air cut the fuel-N conversion.

Fuel NOx (as NO₂)82.111kg/h
Fuel NOx concentration (as NO₂, dry)821.11mg/Nm³

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 1 % N, 25 % conversion. The inputs, in the units selected above:

InputValue
Fuel fired10.000 t/h
Nitrogen in the fuel (as fired)1.0000 %
Conversion of fuel N to NO25.000 %
Flue gas flow (dry, normal)100,000 Nm³/h

Applying the formula below gives:

ResultValue
Fuel NOx (as NO₂)82.111 kg/h
Fuel NOx concentration (as NO₂, dry)821.11 mg/Nm³

Open this example in the calculator and change any input.

Formula

\(\dot m_{NO_x} = \dot m_f\,N\,f\,\frac{M_{NO_2}}{M_N}, \quad c = \frac{\dot m_{NO_x}}{\dot V_n}\)

Variables

Symbol Meaning SI unit
\(\dot m_f\) Fuel fired kg/s
\(N\) Nitrogen in the fuel (as fired) -
\(f\) Conversion of fuel N to NO -
\(\dot V_n\) Flue gas flow (dry, normal) Nm³/s
\(\dot m_{NO_x}\) Fuel NOx (as NO₂) kg/s
\(c_{NO_x}\) Fuel NOx concentration (as NO₂, dry) kg/m³

Method and standards

Mass balance of fuel nitrogen: the share converted to NO is reported as NO₂ mass using IUPAC molar masses. The conversion share carries the whole prediction and is your input.

Where it is used

  • Emission estimates for new fuels.
  • SNCR sizing input.

Common mistakes

  • NO mass instead of NO₂.

Assumptions and limits

  • Dry, normal basis, at the actual O₂: not corrected to a reference O₂. Correct it with the emission O₂ correction calculator before comparing with a limit.
  • The flue gas flow is not checked against the fuel fired; take it from the combustion calculator for the same fuel and excess air.
  • Thermal NOx is not included.

References

  • Mass balance N → NO
  • reported as NO₂ (IUPAC molar masses); conversion share as user input

Questions and answers

What conversion?

Often quoted as 10–40 %, falling as nitrogen content rises and with air staging; it depends on the fuel and burner, so use measured or burner-maker data. The calculator does not check it.

Why report as NO₂?

Regulations express NOx as NO₂ mass, whatever the NO/NO₂ split.

Grate and FBC boilers?

Low furnace temperatures make fuel NOx the main part.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.