Hydrated Lime for SO₂ and HCl Capture

Hydrated lime for dry or semi-dry acid gas removal from SO₂ and HCl loads, removal wanted, stoichiometric ratio and lime purity (1 Ca(OH)₂ per SO₂, ½ per HCl).

Thermal power plantProcess steam and utilitiesSugar mill and cogenerationDistillery and ethanolStack and chimneyDust collector (ESP, bag filter, cyclone)

Inputs

Examples: Dry injectionSpray dryer

Moles of Ca(OH)₂ fed per stoichiometric mole for the SO₂ and HCl removed. Some suppliers quote it on the inlet acid gas instead: convert before entering.

Results

Dry lime utilisation is low; spray-dryer (semi-dry) systems humidify the gas and need less excess.

Stoichiometric Ca(OH)₂78.490kg/h
Commercial hydrated lime170.63kg/h

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Dry injection. The inputs, in the units selected above:

InputValue
Flue gas flow (dry, normal)100,000 Nm³/h
SO₂ at the inlet (dry, at the actual O₂, not corrected)800.00 mg/Nm³
HCl at the inlet (dry, at the actual O₂, not corrected)150.00 mg/Nm³
SO₂ removal70.000 %
HCl removal90.000 %
Stoichiometric ratio (on the acid gas removed)2.0000 -
Ca(OH)₂ content of the lime92.000 %

Applying the formula below gives:

ResultValue
Stoichiometric Ca(OH)₂78.490 kg/h
Commercial hydrated lime170.63 kg/h

Open this example in the calculator and change any input.

Formula

\(\dot m_{st} = \left(\eta_{SO_2}\dot n_{SO_2} + \tfrac12\eta_{HCl}\dot n_{HCl}\right)M_{Ca(OH)_2}, \quad \dot m = \frac{SR\,\dot m_{st}}{p}\)

Variables

Symbol Meaning SI unit
\(\dot V_n\) Flue gas flow (dry, normal) Nm³/s
\(c_{SO_2}\) SO₂ at the inlet (dry, actual O₂) kg/m³
\(c_{HCl}\) HCl at the inlet (dry, actual O₂) kg/m³
\(\eta_{SO_2}\) SO₂ removal -
\(\eta_{HCl}\) HCl removal -
\(SR\) Stoichiometric ratio on the acid gas removed -
\(p\) Ca(OH)₂ content of the lime -
\(\dot m_{st}\) Stoichiometric Ca(OH)₂ kg/s
\(\dot m\) Commercial hydrated lime kg/s

Method and standards

Stoichiometry: 1 mol Ca(OH)₂ per mol SO₂ and ½ mol per mol HCl removed, with molar masses from IUPAC atomic masses. The stoichiometric ratio multiplies the lime for the acid gas removed, not for the inlet acid gas; supplier figures on the inlet basis must be converted.

Where it is used

  • Acid gas control design.
  • Lime budgets.

Common mistakes

  • Quicklime purity used for hydrated lime.

Assumptions and limits

  • Dry, normal basis. The concentrations are at the actual O₂ of the gas, matching the actual dry flow; values corrected to a reference O₂ must be converted back first.

References

  • Stoichiometry Ca(OH)₂ + SO₂ → CaSO₃ + H₂O; Ca(OH)₂ + 2 HCl → CaCl₂ + 2 H₂O

Questions and answers

Why half a mole per HCl?

Each calcium takes two chlorides.

Typical stoichiometric ratio?

About 2–3 for dry injection, lower for spray dryers.

Residue?

Calcium salts in the fly ash; chlorides make it hygroscopic.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.