Balanced Draught: ID Fan Pressure Required

Pressure the ID fan must develop in a balanced-draught boiler: furnace suction plus the gas-side losses of each section, less the stack's natural draught.

Thermal power plantSugar mill and cogenerationChemical and fertiliserThermic fluid heatingPulp and paperBoilerStack and chimneyFan and blowerBoiler attendant and boiler operator examinations

Inputs

Examples: Coal boiler: furnace -5 mmWC, losses 2 600 Pa, stack 180 PaBagasse boiler with wet scrubber, margin 10 %Oil-fired, no dust collector

The negative furnace pressure the control holds, typically a few mmWC.
Enter your specification's pressure margin, if any.

Gas-side losses at MCR

Results

ID fan pressure required (with margin)356.58mmWC
Net requirement before margin324.17mmWC
Furnace suction plus losses336.40mmWC
Gas-side losses331.41mmWC

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Coal boiler: furnace -5 mmWC, losses 2 600 Pa, stack 180 Pa. The inputs, in the units selected above:

InputValue
Furnace suction to hold4.9966 mmWC
Boiler passes, superheater and bank91.774 mmWC
Economiser40.789 mmWC
Air heater, gas side61.183 mmWC
Dust collector (ESP, bag filter, cyclone, scrubber)50.986 mmWC
Ducts, dampers, stack friction and exit loss20.394 mmWC
Natural draught of the stack (from the stack draught calculator)18.355 mmWC
Pressure margin0 %

Applying the formula below gives:

ResultValue
ID fan pressure required (with margin)251.77 mmWC
Net requirement before margin251.77 mmWC
Furnace suction plus losses270.12 mmWC
Gas-side losses265.13 mmWC

Open this example in the calculator and change any input.

Formula

\(\Sigma\Delta p = \Delta p_1 + \Delta p_2 + \Delta p_3 + \Delta p_4 + \Delta p_5 \qquad \Sigma = p_f + \Sigma\Delta p \qquad \Delta p_{net} = \Sigma - \Delta p_s \qquad \Delta p_{ID} = \Delta p_{net}\,(1 + m_p)\)

Variables

Symbol Meaning SI unit
\(p_f\) furnace suction to hold Pa
\(\Delta p_1\) boiler passes, superheater and bank Pa
\(\Delta p_2\) economiser Pa
\(\Delta p_3\) air heater, gas side Pa
\(\Delta p_4\) dust collector Pa
\(\Delta p_5\) ducts, dampers, stack friction and exit loss Pa
\(\Delta p_s\) natural draught of the stack Pa
\(m_p\) pressure margin –
\(\Delta p_{ID}\) ID fan pressure required with margin Pa
\(\Delta p_{net}\) net requirement before margin Pa
\(\Sigma\) furnace suction plus losses Pa
\(\Sigma\Delta p\) gas-side losses Pa

Method and standards

Steady pressure balance along the gas path of a balanced-draught unit: the ID fan supplies whatever the furnace suction and the losses need beyond the stack's natural draught.

Where it is used

  • Checking the draught of balanced-draught boilers.
  • Locating where draught is lost.
  • ID fan pressure estimates.

Common mistakes

  • Forgetting the stack effect of hot gas.
  • Mixing static and total pressure.
  • Ignoring fouled surfaces that add pressure drop.

Assumptions and limits

  • All losses at the same (MCR) flow and gas temperatures.
  • Losses scale with about the square of flow; at part load use the losses at that load.
  • The pressure margin is your input (FireCAD default 0); the fan sizing applies its own flow margin. It is applied to the net requirement after the stack credit; some specifications apply it to the fan's own resistance before the credit, which gives a slightly higher pressure.
  • Use the stack draught at summer conditions, the smallest credit.
  • When the stack draught exceeds the requirement the ID fan pressure is shown as zero; the net requirement shows the surplus as a negative value.

References

  • Pressure balance along the gas path (balanced draught)

Questions and answers

How do I find the ID fan pressure?

Add the furnace suction you hold and every gas-side loss up to the stack exit, then subtract the stack's natural draught. Furnace −5 mmWC (49 Pa) plus 2 600 Pa of losses less 180 Pa of stack draught leaves 2 469 Pa for the ID fan.

Where do the losses come from?

From the boiler maker for the pressure parts, the dust collector maker, and the duct pressure drop calculator for the ducts; all at MCR flow.

Is the stack draught always a credit?

Yes when the gas is lighter than the air; it is larger in winter and at high gas temperatures. Use the summer value, which is the smallest.

Method and article reviewed by FireCAD engineering on 10 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.