Worked example
Example: 3 m³/s, inlet 250 × 500 mm, 10 µm dust. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Gas flow at cyclone conditions | 10,800 m³/h |
| Inlet width | 250.00 mm |
| Inlet height | 500.00 mm |
| Length of the cylindrical body | 2.0000 m |
| Length of the cone | 2.0000 m |
| Gas dynamic viscosity | 2.5000e-05 Pa·s |
| Particle density | 2,000.0 kg/m³ |
| Gas density | 0.85000 kg/m³ |
| Particle size to evaluate | 10.000 µm |
Applying the formula below gives:
| Result | Value |
|---|---|
| Inlet velocity | 24.000 m/s |
| Effective number of turns | 6.0000 |
| Cut size (50 % collected) | 5.5766 µm |
| Collection efficiency for the particle size | 76.279 % |
Open this example in the calculator and change any input.
Formula
\(V_i = \frac{Q}{W H}\)
\(N_e = \frac{1}{H}\left(L_b + \frac{L_c}{2}\right)\)
\(d_{50} = \sqrt{\frac{9 \mu W}{2 \pi N_e V_i (\rho_p - \rho_g)}}\)
\(\eta_d = \frac{1}{1 + (d_{50}/d_p)^2}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(Q\) | gas flow at cyclone conditions | m³/s |
| \(W\) | inlet width | m |
| \(H\) | inlet height | m |
| \(L_b\) | length of the cylindrical body | m |
| \(L_c\) | length of the cone | m |
| \(\mu\) | gas dynamic viscosity | Pa·s |
| \(\rho_p\) | particle density | kg/m³ |
| \(\rho_g\) | gas density | kg/m³ |
| \(d_p\) | particle size | m |
| \(V_i\) | inlet velocity | m/s |
| \(N_e\) | effective number of turns | - |
| \(d_{50}\) | cut size | m |
| \(\eta_d\) | collection efficiency for d_p | - |
Method and standards
Lapple's model treats the outer vortex as a settling chamber: particles must cross the inlet width during N_e turns. The cut size is the diameter collected with 50 % efficiency; the fractional efficiency curve 1/(1 + (d50/d)²) is the fit to Lapple's curve given by Chopey.
Where it is used
- Sizing a pre-collector ahead of a bag filter or ESP.
- Checking a boiler multicyclone after a fuel change.
- Comparing cyclone designs.
Common mistakes
- Using normal (Nm³) flow instead of actual flow at gas temperature.
- Using bulk density of the dust instead of particle density.
- Expecting good collection of particles well below the cut size.
Assumptions and limits
- Standard tangential-inlet cyclone of the Lapple type (inlet about half the body diameter high and a quarter wide). The dimensions are not checked against that geometry; for other proportions the result is only indicative.
- The 10–30 m/s inlet velocity warning is a common design range, not a limit from the method.
- Efficiency curve for a single particle size; integrate over the size distribution for the overall efficiency.
- Re-entrainment and hopper leakage not included.
References
- Lapple (1951) cut size
- Chopey
- Handbook of Chemical Engineering Calculations (efficiency curve)
Questions and answers
What is the cut size of a cyclone?
The particle size collected with 50 % efficiency. For a 250 × 500 mm inlet taking 3 m³/s with 2 m body and 2 m cone, it is about 5.6 µm for 2 000 kg/m³ dust.
How efficient is a cyclone for 10 µm dust?
By the Lapple curve η = 1/(1 + (d50/d)²): about 76 % in the example above.
How do I make a cyclone collect finer dust?
Raise the inlet velocity (within pressure drop limits), use a narrower inlet or a longer body and cone, or use several small cyclones in parallel.
Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.