FireCADCalc

Ringelmann Number and Smoke Opacity Converter

Converts a Ringelmann smoke number to opacity and an opacity reading to its Ringelmann number, with transmittance and optical density.

Thermal power plantSugar mill and cogenerationChemical and fertiliserPulp and paperBoilerStack and chimney

Inputs

Examples: Ringelmann 1, opacity reading 20 %Ringelmann 2, reading 35 %Ringelmann 0.5, reading 8 %

Results

Opacity of the Ringelmann number40.000%
Ringelmann number of the reading1.7500
Transmittance of the reading65.000%
Optical density of the reading0.18709

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Ringelmann 1, opacity reading 20 %. The inputs, in the units selected above:

InputValue
Ringelmann number (0–5)1.0000 -
Opacity reading (opacity meter)20.000 %

Applying the formula below gives:

ResultValue
Opacity of the Ringelmann number20.000 %
Ringelmann number of the reading1.0000
Transmittance of the reading80.000 %
Optical density of the reading0.096910

Open this example in the calculator and change any input.

Formula

\(O_N = 0.20\,N \qquad N_O = \frac{O}{0.20} \qquad \tau = 1 - O \qquad D = -\log_{10}(1 - O)\)

Variables

Symbol Meaning SI unit
\(N\) Ringelmann number –
\(O\) opacity reading –
\(O_N\) opacity of the Ringelmann number –
\(N_O\) Ringelmann number of the reading –
\(\tau\) transmittance –
\(D\) optical density –

Method and standards

The Ringelmann chart defines each number as 20 % blackness; opacity, transmittance and optical density follow from their definitions.

Where it is used

  • Smoke observations for permits and inspections.
  • Comparing visual readings with an opacity meter.
  • Combustion troubleshooting (black smoke).

Common mistakes

  • Reading smoke against the sun or a bright sky.
  • Comparing opacity readings taken at different stack diameters (path length).
  • Treating opacity as dust concentration without calibration.

Assumptions and limits

  • Opacity at the stack exit path length; no path-length correction.
  • Ringelmann numbers are read by an observer against a printed chart of blackness; equating each number with 20 % instrument opacity is a convention. Observer readings and transmissometer opacity can differ, especially for coloured smoke or in poor light.
  • The two conversions are independent: the Ringelmann number gives only \(O_N\), and the opacity reading gives \(N_O\), \(\tau\) and \(D\).

References

  • Ringelmann smoke chart (U.S. Bureau of Mines IC 8333): each number is 20 % black

Questions and answers

What is Ringelmann number 1?

20 % black, an opacity of 20 %. Each number adds 20 %: No. 2 is 40 %, No. 5 is fully black.

How do I convert an opacity meter reading?

Divide by 20 %: a reading of 35 % is Ringelmann 1.75. The transmittance is 65 % and the optical density 0.19.

Is Ringelmann still used?

Many permits and inspectors still state smoke limits as Ringelmann numbers; opacity meters give the same information continuously.

Method and article reviewed by FireCAD engineering on 11 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.