Worked example
Example: Ringelmann 1, opacity reading 20 %. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Ringelmann number (0–5) | 1.0000 - |
| Opacity reading (opacity meter) | 20.000 % |
Applying the formula below gives:
| Result | Value |
|---|---|
| Opacity of the Ringelmann number | 20.000 % |
| Ringelmann number of the reading | 1.0000 |
| Transmittance of the reading | 80.000 % |
| Optical density of the reading | 0.096910 |
Open this example in the calculator and change any input.
Formula
\(O_N = 0.20\,N \qquad N_O = \frac{O}{0.20} \qquad \tau = 1 - O \qquad D = -\log_{10}(1 - O)\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(N\) | Ringelmann number | – |
| \(O\) | opacity reading | – |
| \(O_N\) | opacity of the Ringelmann number | – |
| \(N_O\) | Ringelmann number of the reading | – |
| \(\tau\) | transmittance | – |
| \(D\) | optical density | – |
Method and standards
The Ringelmann chart defines each number as 20 % blackness; opacity, transmittance and optical density follow from their definitions.
Where it is used
- Smoke observations for permits and inspections.
- Comparing visual readings with an opacity meter.
- Combustion troubleshooting (black smoke).
Common mistakes
- Reading smoke against the sun or a bright sky.
- Comparing opacity readings taken at different stack diameters (path length).
- Treating opacity as dust concentration without calibration.
Assumptions and limits
- Opacity at the stack exit path length; no path-length correction.
- Ringelmann numbers are read by an observer against a printed chart of blackness; equating each number with 20 % instrument opacity is a convention. Observer readings and transmissometer opacity can differ, especially for coloured smoke or in poor light.
- The two conversions are independent: the Ringelmann number gives only \(O_N\), and the opacity reading gives \(N_O\), \(\tau\) and \(D\).
References
- Ringelmann smoke chart (U.S. Bureau of Mines IC 8333): each number is 20 % black
Questions and answers
What is Ringelmann number 1?
20 % black, an opacity of 20 %. Each number adds 20 %: No. 2 is 40 %, No. 5 is fully black.
How do I convert an opacity meter reading?
Divide by 20 %: a reading of 35 % is Ringelmann 1.75. The transmittance is 65 % and the optical density 0.19.
Is Ringelmann still used?
Many permits and inspectors still state smoke limits as Ringelmann numbers; opacity meters give the same information continuously.
Method and article reviewed by FireCAD engineering on 11 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.