Worked example
Example: 40 m, 30 °C air, 300 °C gas, 150 °C with a fan. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Chimney height above the grate | 40.000 m |
| Outside air temperature | 30.000 °C |
| Mean flue gas temperature in the chimney | 300.00 °C |
| Gas temperature leaving if a fan made the draught | 150.00 °C |
| Barometric pressure | 1.0132 bar |
| Molar mass of the flue gas | 30.000 kg/kmol |
| Specific heat of the flue gas | 1.0050 kJ/(kg·K) |
Applying the formula below gives:
| Result | Value |
|---|---|
| Density of the outside air | 1.1644 kg/m³ |
| Density of the flue gas | 0.63787 kg/m³ |
| Theoretical draught | 21.062 mmWC |
| Draught as a column of hot gas | 33.019 m |
| Theoretical gas velocity √(2 g H_g) | 25.448 m/s |
| Chimney efficiency | 0.21480 % |
Open this example in the calculator and change any input.
Formula
\(\Delta p = g\, H\,(\rho_a - \rho_g), \quad \rho = \frac{p\, M}{R\, T}\)
\(H_g = H \left(\frac{\rho_a}{\rho_g} - 1\right), \quad V = \sqrt{2 g H_g}\)
\(\eta_{ch} = \frac{g\, H_g}{c_p\, (T_g - T_f)}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(H\) | Chimney height above the grate | m |
| \(T_a\) | Outside air temperature | K |
| \(T_g\) | Mean flue gas temperature in the chimney | K |
| \(T_f\) | Gas temperature leaving if a fan made the draught | K |
| \(p_b\) | Barometric pressure | Pa |
| \(M_g\) | Molar mass of the flue gas | kg/kmol |
| \(M\) | molar mass in the density equation: \(M_g\) for the gas, 28.96 kg/kmol (dry air) for the outside air | kg/kmol |
| \(R\) | universal gas constant, 8314.46 | J/(kmol·K) |
| \(p\) | barometric pressure \(p_b\) | Pa |
| \(g\) | standard gravity, 9.80665 | m/s² |
| \(c_p\) | Specific heat of the flue gas | J/(kg·K) |
| \(\rho_a\) | Density of the outside air | kg/m³ |
| \(\rho_g\) | Density of the flue gas | kg/m³ |
| \(\Delta p\) | Theoretical draught | Pa |
| \(H_g\) | Draught as a column of hot gas | m |
| \(V\) | Theoretical gas velocity √(2 g H_g) | m/s |
| \(\eta_{ch}\) | Chimney efficiency | - |
Method and standards
Hydrostatic pressure difference between a column of outside air and a column of hot flue gas of the same height, with ideal-gas densities.
Worked example
A chimney is 40 m high; air outside is at 30 °C and the flue gas averages 300 °C. With a fan the gas could leave at 150 °C. Take gas c_p 1.005 kJ/(kg·K).
- ρ_air = 1.164 kg/m³; ρ_gas (M 30) = 0.638 kg/m³
- Draught = 9.807 × 40 × (1.164 − 0.638) = 206.6 Pa = 21.1 mm of water
- Hot gas column = 40 × (1.164/0.638 − 1) = 33.0 m
- Efficiency = 9.807 × 33.0 / (1005 × 150) = 0.21 %
Where it is used
- Boiler attendant and operator examinations.
- First estimate of chimney height for a small boiler.
- Explaining the cost of natural draught.
Common mistakes
- Using gauge pressure for density.
- Taking theoretical draught as available draught (friction is lost).
- Using the same temperature for air and gas.
Assumptions and limits
- Static (theoretical) draught; friction and velocity losses not deducted.
- Uniform gas temperature in the chimney.
References
- Natural draught by hydrostatics with ideal-gas densities (textbook)
Questions and answers
What draught does a 40 m chimney give with gas at 300 °C and air at 30 °C?
206.6 Pa, or 21.1 mm of water. As a column of hot gas, 33.0 m, with a theoretical velocity of 25.4 m/s.
What is chimney efficiency?
The work the hot-gas column does per kg of gas, divided by the extra heat thrown away by sending the gas up hot instead of cooling it to the fan-draught temperature. Here 0.21 %.
Why is it so low?
Natural draught is bought with stack heat. That is why large boilers use fans and recover the heat.
Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.