Worked example
Example: Ganapathy: 1.5 % at 400 °F. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Ash in the flue gas (by weight, wet gas) | 1.5000 % |
| Gas temperature | 204.44 °C |
| Gas pressure (absolute) | 101.33 kPa |
| Gas molar mass (wet gas) | 28.800 kg/kmol |
Applying the formula below gives:
| Result | Value |
|---|---|
| Gas density at t | 0.73488 kg/m³ |
| Concentration, actual | 11.023 g/m³ |
| Concentration per US standard ft³ (60 °F, 14.696 psia) | 7.9687 gr/scf |
| Concentration at 0 °C, 101.325 kPa | 19,274 mg/Nm³ |
Open this example in the calculator and change any input.
Formula
\(C_a = A\,\rho_g, \quad \rho_g = \frac{p\,MW}{R\,T}\)
\(C_s = A\,\frac{p_0\,MW}{R\,T_s}, \quad C_N = A\,\frac{p_0\,MW}{R\,T_N}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(A\) | Ash in the flue gas (by weight) | - |
| \(t\) | Gas temperature | K |
| \(p\) | Gas pressure (absolute) | Pa |
| \(MW\) | Gas molar mass | kg/kmol |
| \(\rho_g\) | Gas density at t | kg/m³ |
| \(T\) | gas temperature \(t\) in kelvin | K |
| \(R\) | universal gas constant, 8314.46 | J/(kmol·K) |
| \(p_0\) | reference pressure, 101 325 | Pa |
| \(T_s\) | standard temperature, 60 °F = 288.71 | K |
| \(T_N\) | normal temperature, 0 °C = 273.15 | K |
| \(C_a\) | Concentration, actual | kg/m³ |
| \(C_s\) | Concentration at 60 °F (standard ft³) | kg/m³ |
| \(C_N\) | Concentration at 0 °C, 101.325 kPa | kg/m³ |
Method and standards
Definition with ideal-gas density (Ganapathy uses 39.5/(460 + t) lb/ft³ for MW 28.8).
Where it is used
- Dust collector sizing.
- Emission reporting.
Common mistakes
- Mixing actual and normal volumes.
- Using wet and dry bases together.
Assumptions and limits
- Ideal gas; dust volume negligible.
- The ash share and molar mass are for the wet gas as it flows. Emission limits are usually quoted on dry gas at a reference O₂; convert with the emission O₂ correction calculator.
- \(C_a\) is per actual volume at the gas temperature. \(C_s\) and \(C_N\) are the same concentration per standard volume: gr/scf is per US standard cubic foot (60 °F, 14.696 psia), mg/Nm³ per normal cubic metre (0 °C, 101.325 kPa), and the units convert between the two reference states.
References
- Ganapathy
- Steam Plant Calculations Manual
- 2nd ed. (Marcel Dekker, 1993)
- Q2.16b
- Eq. (12b)
- Ideal-gas density; standard 60 °F (288.71 K) and normal 0 °C at 101.325 kPa
Questions and answers
Why grains per cubic foot?
US dust-collector makers quote loadings in grains/acf or grains/scf; 1 grain = 64.8 mg.
What does Ganapathy's example give?
1.5 % ash at 400 °F: 4.8 grains/acf, or 8.0 grains/scf at 60 °F.
Actual or standard?
Collectors are sized on actual volume; emission limits use normal or standard volume.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.