Worked example
Example: 60 t/h thin stillage, 3.5 economy. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Thin stillage to the evaporator | 60.000 t/h |
| Total solids in thin stillage | 6.0000 % |
| Total solids in syrup | 30.000 % |
| Evaporator economy (kg vapour per kg steam) | 3.5000 - |
| Wet cake from the centrifuges | 25.000 t/h |
| Total solids in wet cake | 35.000 % |
| Total solids in DDGS | 90.000 % |
| Dryer heat per kg of water evaporated | 3,500.0 kJ/kg |
Applying the formula below gives:
| Result | Value |
|---|---|
| Syrup | 12.000 t/h |
| Evaporator evaporation | 48.000 t/h |
| Evaporator steam | 13.714 t/h |
| DDGS (cake and syrup dried) | 13.722 t/h |
| Dryer evaporation | 23.278 t/h |
| Dryer heat | 22.631 MW |
Open this example in the calculator and change any input.
Formula
\(\dot m_s = \frac{\dot m_t x_t}{x_s}, \quad E = \dot m_t - \dot m_s, \quad \dot m_D = \frac{\dot m_s x_s + \dot m_c x_c}{x_d}, \quad E_d = \dot m_s + \dot m_c - \dot m_D\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\dot m_t\) | Thin stillage to the evaporator | kg/s |
| \(x_t\) | Total solids in thin stillage | - |
| \(x_s\) | Total solids in syrup | - |
| \(\varepsilon\) | Evaporator economy (kg vapour per kg steam) | - |
| \(\dot m_c\) | Wet cake from the centrifuges | kg/s |
| \(x_c\) | Total solids in wet cake | - |
| \(x_d\) | Total solids in DDGS | - |
| \(q_d\) | Dryer heat per kg of water evaporated | J/kg |
| \(\dot m_s\) | Syrup | kg/s |
| \(E\) | Evaporator evaporation | kg/s |
| \(\dot m_{st}\) | Evaporator steam | kg/s |
| \(\dot m_D\) | DDGS (cake and syrup dried) | kg/s |
| \(E_d\) | Dryer evaporation | kg/s |
| \(\dot Q_d\) | Dryer heat | W |
Method and standards
Total-solids balance.
Where it is used
- Dryhouse design.
- Energy audits of grain distilleries.
Common mistakes
- Counting backset in the evaporator feed.
- Mixing dry and wet basis.
Assumptions and limits
- No solids lost.
- The dryer heat is on the basis of the heat per kg entered (fuel heat input or heat delivered to the dryer).
References
- Jacques
- Lyons and Kelsall (eds.)
- The Alcohol Textbook
- 4th ed. (Nottingham University Press, 2003)
- ch. 26 (Meredith)
- dryhouse design
- Total-solids balance
Questions and answers
Why evaporate before drying?
A multiple-effect evaporator removes several kilograms of water per kilogram of steam; a dryer needs more than one kilogram of fuel heat per kilogram of water.
Why does syrup solids content stop at 25–50 %?
Suspended solids and viscosity foul the evaporator tubes; clarified thin stillage goes further.
Is backset counted?
Thin stillage returned as backset never reaches the evaporator; enter only the evaporator feed.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.