FireCADCalc

Ethanol Storage Tanks: Days, Volume at 20 °C

Storage volume for a production rate and days of storage with ullage, tank count, and the volume a stock at a temperature occupies at 20 °C.

Distillery and ethanolTank and drum

Inputs

Examples: 100 KLPD, 30 days60 KLPD, 15 days

Results

A linear expansion coefficient is adequate for a few tens of degrees; use the official tables for excise.

Stock to hold900.00m³
Nominal tankage978.26m³
Tanks2.0000
Volume at 20 °C per unit volume at stock temperature1.0055

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 100 KLPD, 30 days. The inputs, in the units selected above:

InputValue
Production100.00 kL/d
Days of storage30.000 d
Ullage (empty share at full)5.0000 %
One tank, nominal1,000.0 m³
Stock temperature35.000 °C
Cubic expansion coefficient1,100.0 µm/(m·K)

Applying the formula below gives:

ResultValue
Stock to hold3,000.0 m³
Nominal tankage3,157.9 m³
Tanks4.0000
Volume at 20 °C per unit volume at stock temperature0.98350

Open this example in the calculator and change any input.

Formula

\(V_n = \frac{\dot V t}{1 - u}, \quad N = \lceil V_n / V_{tank} \rceil, \quad \frac{V_{20}}{V_T} = 1 - \beta (T - 20\,^\circ C)\)

Variables

Symbol Meaning SI unit
\(\dot V\) Production m³/s
\(t\) Days of storage s
\(u\) Ullage (empty share at full) -
\(V_{tank}\) One tank, nominal m³
\(T\) Stock temperature K
\(\beta\) Cubic expansion coefficient 1/K
\(V_s\) Stock to hold m³
\(V_n\) Nominal tankage m³
\(N\) Tanks -
\(V_{20}/V_T\) Volume at 20 °C per unit volume at stock temperature -

Method and standards

Definitions.

Where it is used

  • Tank farm sizing.
  • Stock reconciliation.

Common mistakes

  • Nominal tank volume taken as working volume.

Assumptions and limits

  • Linear expansion with the β you enter; the default 1.1 × 10⁻³ /K is a round figure for high-strength ethanol near room temperature, not an official value. The OIML R 22 density formula (used in the steel tank and spirit stock calculators) is more exact; use the official tables for excise.

References

  • V = Q t/(1 − u); V₂₀ = V_T [1 − β (T − 20 °C)] (linear expansion)

Questions and answers

Expansion coefficient of ethanol?

About 1.1 × 10⁻³ per K near room temperature.

Why ullage?

Space for expansion and to keep the level below the overflow and vent.

Days of storage?

Set by dispatch schedule and oil-company lifting; 15–30 days is common.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.