FireCADCalc

Decanter: Wet Cake and Thin Stillage from Whole Stillage

Wet cake and thin stillage from a decanter centrifuge by a two-stream solids balance from the whole stillage flow and the solids of each stream.

Distillery and ethanol

Inputs

Examples: 40 t/h whole stillageHigh capture

Results

Wet cake9.2308t/h
Thin stillage30.769t/h
Solids captured in cake58.580%

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 40 t/h whole stillage. The inputs, in the units selected above:

InputValue
Whole stillage40.000 t/h
Solids in whole stillage13.000 %
Solids in wet cake33.000 %
Solids in thin stillage7.0000 %

Applying the formula below gives:

ResultValue
Wet cake9.2308 t/h
Thin stillage30.769 t/h
Solids captured in cake58.580 %

Open this example in the calculator and change any input.

Formula

\(\dot m_c = \dot m_f \frac{x_f - x_t}{x_c - x_t}, \quad \dot m_t = \dot m_f - \dot m_c, \quad \eta_s = \frac{\dot m_c x_c}{\dot m_f x_f}\)

Variables

Symbol Meaning SI unit
\(\dot m_f\) Whole stillage kg/s
\(x_f\) Solids in whole stillage -
\(x_c\) Solids in wet cake -
\(x_t\) Solids in thin stillage -
\(\dot m_c\) Wet cake kg/s
\(\dot m_t\) Thin stillage kg/s
\(\eta_s\) Solids captured in cake -

Method and standards

Solids balance.

Where it is used

  • Decanter sizing and checks.

Common mistakes

  • Suspended and dissolved solids mixed between streams.

Assumptions and limits

  • Steady state.

References

  • Two-product solids balance

Questions and answers

Why a decanter?

It removes suspended solids so the thin stillage can be evaporated and recycled.

Solids capture?

The share of feed solids leaving in the cake.

Polymer?

Flocculant raises capture but adds cost.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.