FireCADCalc

CIP: Caustic per Clean and per Year

Caustic soda for one cleaning-in-place make-up from the CIP solution volume, strength and density and the caustic purity, and the yearly use.

Distillery and ethanolFood, dairy and textile

Inputs

Examples: 10 m3 at 2 %, lyeFlakes

Results

Recovered CIP caustic is topped up rather than remade: use the top-up volume for recovery systems.

NaOH (100 %) per clean91.350kg
Commercial caustic per clean93.214kg
Commercial caustic per year18.643t

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 10 m3 at 2 %, lye. The inputs, in the units selected above:

InputValue
CIP solution volume per clean10.000 m³
Caustic strength of the solution (w/w)2.0000 %
Solution density1,020.0 kg/m³
Caustic purity (flake 0.98, lye 0.48)48.000 %
Cleans per year300.00 -

Applying the formula below gives:

ResultValue
NaOH (100 %) per clean204.00 kg
Commercial caustic per clean425.00 kg
Commercial caustic per year127.50 t

Open this example in the calculator and change any input.

Formula

\(m_{NaOH} = V \rho w, \quad m_p = \frac{m_{NaOH}}{p}, \quad M_a = m_p N\)

Variables

Symbol Meaning SI unit
\(V\) CIP solution volume per clean m³
\(w\) Caustic strength of the solution (w/w) -
\(\rho\) Solution density kg/m³
\(p\) Caustic purity (flake 0.98, lye 0.48) -
\(N\) Cleans per year -
\(m_{NaOH}\) NaOH (100 %) per clean kg
\(m_p\) Commercial caustic per clean kg
\(M_a\) Commercial caustic per year kg

Method and standards

Mass balance.

Where it is used

  • Chemical consumption budgets.

Common mistakes

  • Volume % used for w/w.

Assumptions and limits

  • Fresh make-up of the whole volume every clean; with caustic recovery enter the top-up volume instead.

References

  • Mass balance m = V ρ w / p

Questions and answers

Why clean fermenters?

Bacterial contamination eats sugar and makes acids, cutting yield.

Typical strength?

1–3 % NaOH, hot, then rinse; acid washes remove scale.

Lye or flakes?

Enter the purity of what you buy: 48 % lye or 98 % flakes.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.