FireCADCalc

Thoma Cavitation Parameter and NPSH Required from Specific Speeds

Thoma cavitation number sigma = NPSHR/H, from the specific speed and suction specific speed, the NPSH required and the margin against an available NPSH.

Thermal power plantProcess steam and utilitiesRefinery and petrochemicalChemical and fertiliser

Inputs

Examples: 1,480 rpm, 60 m, 0.1 m3/s, S 9,000Boiler feed stage 2,980 rpm, 200 m, 0.08 m3/s, S 8,500Mixed flow 980 rpm, 15 m, 0.6 m3/s, S 11,000

Accepted: 0.5 to 2,000 m
Accepted: 9.5493 to 9,549.3 rpm
Accepted: 0.036 to 72,000 m³/h
Accepted: 3,000 to 20,000
Accepted: 0 to 200 m

Results

Both specific speeds are in US units (rpm, gpm, ft) at best efficiency; for a double-suction impeller use half the flow. Suction specific speeds of 8,500-11,000 are common; higher values need more care with recirculation at low flow. NPSHR here is the 3 % head-drop value; keep a margin above it.

Specific speed (US units)5,143.6
Thoma parameter0.36293
NPSH required5.4440m
NPSH margin ratio1.6532

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 1,480 rpm, 60 m, 0.1 m3/s, S 9,000. The inputs, in the units selected above:

InputValue
Pump head per stage60.000 m
Speed1,480.0 rpm
Flow per impeller eye360.00 m³/h
Suction specific speed (US units)9,000.0 -
NPSH available6.0000 m

Applying the formula below gives:

ResultValue
Specific speed (US units)1,121.2
Thoma parameter0.062218
NPSH required3.7331 m
NPSH margin ratio1.6073

Open this example in the calculator and change any input.

Formula

\(\sigma = \frac{NPSH_R}{H} = \left(\frac{n_s}{S}\right)^{4/3}, \quad n_s = \frac{n\sqrt Q}{H^{3/4}}, \quad S = \frac{n\sqrt Q}{NPSH_R^{3/4}}\)

Variables

Symbol Meaning SI unit
\(H\) Pump head per stage m
\(n\) Speed rad/s
\(Q\) Flow per impeller eye m³/s
\(S\) Suction specific speed (US units) -
\(NPSH_A\) NPSH available m
\(n_s\) Specific speed (US units) -
\(\sigma\) Thoma parameter -
\(NPSH_R\) NPSH required m
\(NPSH_A/NPSH_R\) NPSH margin ratio -

Method and standards

Thoma parameter and suction specific speed.

Where it is used

  • Preliminary NPSH checks.
  • Choosing between single- and double-suction pumps.

Common mistakes

  • Using SI specific speeds with US-unit S values.
  • Using the total flow of a double-suction pump.

Assumptions and limits

  • Best-efficiency point; 3 % head-drop criterion.

Questions and answers

Why does σ grow with specific speed?

Higher specific speed pumps make less head for their eye size, so the NPSH needed is a larger fraction of the head; σ = (n_s/S)^{4/3}.

Is σ used for turbines too?

Yes: Thoma introduced it for hydraulic turbines, where it sets the setting of the runner below tailwater.

What do the defaults represent?

A 1,480 rpm pump making 60 m at 0.1 m³/s through one eye with S = 9,000: n_s = 1,121, σ = 0.062 and NPSHR 3.7 m, so 6 m available gives a 1.6 margin ratio.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Karassik, Messina, Cooper and Heald, Pump Handbook, 4th ed. (McGraw-Hill, 2008), sec. 2.1.3, eqs. 18-20 and Figs. 25-26

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.