Worked example
Example: 1,480 rpm, 60 m, 0.1 m3/s, S 9,000. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Pump head per stage | 60.000 m |
| Speed | 1,480.0 rpm |
| Flow per impeller eye | 360.00 m³/h |
| Suction specific speed (US units) | 9,000.0 - |
| NPSH available | 6.0000 m |
Applying the formula below gives:
| Result | Value |
|---|---|
| Specific speed (US units) | 1,121.2 |
| Thoma parameter | 0.062218 |
| NPSH required | 3.7331 m |
| NPSH margin ratio | 1.6073 |
Open this example in the calculator and change any input.
Formula
\(\sigma = \frac{NPSH_R}{H} = \left(\frac{n_s}{S}\right)^{4/3}, \quad n_s = \frac{n\sqrt Q}{H^{3/4}}, \quad S = \frac{n\sqrt Q}{NPSH_R^{3/4}}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(H\) | Pump head per stage | m |
| \(n\) | Speed | rad/s |
| \(Q\) | Flow per impeller eye | m³/s |
| \(S\) | Suction specific speed (US units) | - |
| \(NPSH_A\) | NPSH available | m |
| \(n_s\) | Specific speed (US units) | - |
| \(\sigma\) | Thoma parameter | - |
| \(NPSH_R\) | NPSH required | m |
| \(NPSH_A/NPSH_R\) | NPSH margin ratio | - |
Method and standards
Thoma parameter and suction specific speed.
Where it is used
- Preliminary NPSH checks.
- Choosing between single- and double-suction pumps.
Common mistakes
- Using SI specific speeds with US-unit S values.
- Using the total flow of a double-suction pump.
Assumptions and limits
- Best-efficiency point; 3 % head-drop criterion.
Questions and answers
Why does σ grow with specific speed?
Higher specific speed pumps make less head for their eye size, so the NPSH needed is a larger fraction of the head; σ = (n_s/S)^{4/3}.
Is σ used for turbines too?
Yes: Thoma introduced it for hydraulic turbines, where it sets the setting of the runner below tailwater.
What do the defaults represent?
A 1,480 rpm pump making 60 m at 0.1 m³/s through one eye with S = 9,000: n_s = 1,121, σ = 0.062 and NPSHR 3.7 m, so 6 m available gives a 1.6 margin ratio.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Karassik, Messina, Cooper and Heald, Pump Handbook, 4th ed. (McGraw-Hill, 2008), sec. 2.1.3, eqs. 18-20 and Figs. 25-26