FireCADCalc

Power Pump Displacement, Volumetric Efficiency and Torque

Displacement of a single- or double-acting plunger pump, plunger speed, volumetric efficiency with liquid compressibility, delivered flow, power and torque.

Thermal power plantProcess steam and utilitiesRefinery and petrochemicalChemical and fertiliser

Inputs

Examples: Triplex 2 in x 5 in, 360 rpm, 1,500 psi waterDuplex double-acting 6 in piston, 1.75 in rod, 10 in, 80 rpm, 300 psiQuintuplex 1.25 in x 3 in, 450 rpm, 6,000 psi propane

Accepted: 0.19685 to 19.685 in
Accepted: 0.19685 to 39.37 in
Accepted: 1 to 12
Accepted: 9.5493 to 1,909.9 rpm
Accepted: 0 to 0.3 m
Accepted: 1.4504 to 29,008 psi
Accepted: 0 to 6.895E-5 1/psi
Accepted: 1 to 20
Accepted: 0 to 50 %
Accepted: 50 to 100 %

Results

The ratio r is the liquid volume between the valves at the end of the suction stroke (clearance C plus displacement D) over D. Compressibility matters above about 400 bar for water, and much earlier for light hydrocarbons. Standards limit plunger speed to about 0.7-1.4 m/s.

Displacement35.859US gal/min
Mean plunger speed225.00ft/min
Volumetric efficiency (suction basis)41.455%
Volumetric efficiency (discharge basis)36.000%
Delivered flow (suction basis)14.865US gal/min
Displacement power93.591kW
Input power103.99kW
Input torque2,206.7N·m

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Triplex 2 in x 5 in, 360 rpm, 1,500 psi water. The inputs, in the units selected above:

InputValue
Plunger or piston diameter2.0000 in
Stroke (full plunger travel)5.0000 in
Number of plungers3.0000 -
Crankshaft speed360.00 rpm
ActionSingle acting
Piston rod diameter (double acting)0 m
Differential pressure1,500.0 psi
Liquid compressibility3.2000e-06 1/psi
Ratio r = (C + D)/D4.0000 -
Slip3.0000 %
Mechanical efficiency90.000 %

Applying the formula below gives:

ResultValue
Displacement73.440 US gal/min
Mean plunger speed300.00 ft/min
Volumetric efficiency (suction basis)95.553 %
Volumetric efficiency (discharge basis)95.080 %
Delivered flow (suction basis)70.174 US gal/min
Displacement power47.919 kW
Input power53.243 kW
Input torque1,412.3 N·m

Open this example in the calculator and change any input.

Formula

\(D = A\,m\,n\,s\ \ (\text{double acting: }(2A - a)mns), \quad VE_s = \frac{1 - P_{td}\beta r}{1 - P_{td}\beta} - S, \quad VE_d = 1 - P_{td}\beta r - S\)

\(P_{in} = \frac{D\,P_{td}}{ME}, \quad M = \frac{P_{in}}{\omega}\)

Variables

Symbol Meaning SI unit
\(d_p\) Plunger or piston diameter m
\(s\) Stroke (full plunger travel) m
\(m\) Number of plungers -
\(n\) Crankshaft speed rad/s
\(\text{acting}\) Action -
\(d_r\) Piston rod diameter (double acting) m
\(P_{td}\) Differential pressure Pa
\(\beta\) Liquid compressibility 1/Pa
\(r\) Ratio r = (C + D)/D -
\(S\) Slip -
\(ME\) Mechanical efficiency -
\(D\) Displacement m³/s
\(S_p\) Mean plunger speed m/s
\(VE_s\) Volumetric efficiency (suction basis) -
\(VE_d\) Volumetric efficiency (discharge basis) -
\(Q\) Delivered flow (suction basis) m³/s
\(P_{displ}\) Displacement power W
\(P_{in}\) Input power W
\(M\) Input torque N·m

Method and standards

Power pump theory.

Where it is used

  • Sizing triplex and quintuplex pumps.
  • High-pressure and compressible-liquid service.

Common mistakes

  • Ignoring compressibility at high pressure.
  • Using half the stroke in the displacement.

Assumptions and limits

  • Constant compressibility over the pressure range.

Questions and answers

Why two volumetric efficiencies?

Delivered volume is usually measured at suction pressure; expanded back from discharge pressure the liquid occupies more volume, so the suction-basis efficiency is higher than the discharge-basis one.

Is the stroke half the travel?

No: The definition line says half, but the displacement and plunger-speed formulas (D = A m n s/231 and S_p = s n/6) use the full plunger travel, as here.

What do the defaults represent?

A triplex with 2 in plungers and a 5 in stroke at 360 rpm, 1,500 psi, water compressibility 3.2 × 10⁻⁶ /psi, r = 4 and 3 % slip: 73.4 gpm displacement, 300 ft/min plunger speed, 95.6 % volumetric efficiency, 70.2 gpm delivered and 53.3 kW input at 90 % mechanical efficiency.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Karassik, Messina, Cooper and Heald, Pump Handbook, 4th ed. (McGraw-Hill, 2008), sec. 3.1, power pump theory (displacement, slip, volumetric and mechanical efficiency, torque)

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.