Worked example
Example: Triplex 2 in x 5 in, 360 rpm, 1,500 psi water. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Plunger or piston diameter | 2.0000 in |
| Stroke (full plunger travel) | 5.0000 in |
| Number of plungers | 3.0000 - |
| Crankshaft speed | 360.00 rpm |
| Action | Single acting |
| Piston rod diameter (double acting) | 0 m |
| Differential pressure | 1,500.0 psi |
| Liquid compressibility | 3.2000e-06 1/psi |
| Ratio r = (C + D)/D | 4.0000 - |
| Slip | 3.0000 % |
| Mechanical efficiency | 90.000 % |
Applying the formula below gives:
| Result | Value |
|---|---|
| Displacement | 73.440 US gal/min |
| Mean plunger speed | 300.00 ft/min |
| Volumetric efficiency (suction basis) | 95.553 % |
| Volumetric efficiency (discharge basis) | 95.080 % |
| Delivered flow (suction basis) | 70.174 US gal/min |
| Displacement power | 47.919 kW |
| Input power | 53.243 kW |
| Input torque | 1,412.3 N·m |
Open this example in the calculator and change any input.
Formula
\(D = A\,m\,n\,s\ \ (\text{double acting: }(2A - a)mns), \quad VE_s = \frac{1 - P_{td}\beta r}{1 - P_{td}\beta} - S, \quad VE_d = 1 - P_{td}\beta r - S\)
\(P_{in} = \frac{D\,P_{td}}{ME}, \quad M = \frac{P_{in}}{\omega}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(d_p\) | Plunger or piston diameter | m |
| \(s\) | Stroke (full plunger travel) | m |
| \(m\) | Number of plungers | - |
| \(n\) | Crankshaft speed | rad/s |
| \(\text{acting}\) | Action | - |
| \(d_r\) | Piston rod diameter (double acting) | m |
| \(P_{td}\) | Differential pressure | Pa |
| \(\beta\) | Liquid compressibility | 1/Pa |
| \(r\) | Ratio r = (C + D)/D | - |
| \(S\) | Slip | - |
| \(ME\) | Mechanical efficiency | - |
| \(D\) | Displacement | m³/s |
| \(S_p\) | Mean plunger speed | m/s |
| \(VE_s\) | Volumetric efficiency (suction basis) | - |
| \(VE_d\) | Volumetric efficiency (discharge basis) | - |
| \(Q\) | Delivered flow (suction basis) | m³/s |
| \(P_{displ}\) | Displacement power | W |
| \(P_{in}\) | Input power | W |
| \(M\) | Input torque | N·m |
Method and standards
Power pump theory.
Where it is used
- Sizing triplex and quintuplex pumps.
- High-pressure and compressible-liquid service.
Common mistakes
- Ignoring compressibility at high pressure.
- Using half the stroke in the displacement.
Assumptions and limits
- Constant compressibility over the pressure range.
Questions and answers
Why two volumetric efficiencies?
Delivered volume is usually measured at suction pressure; expanded back from discharge pressure the liquid occupies more volume, so the suction-basis efficiency is higher than the discharge-basis one.
Is the stroke half the travel?
No: The definition line says half, but the displacement and plunger-speed formulas (D = A m n s/231 and S_p = s n/6) use the full plunger travel, as here.
What do the defaults represent?
A triplex with 2 in plungers and a 5 in stroke at 360 rpm, 1,500 psi, water compressibility 3.2 × 10⁻⁶ /psi, r = 4 and 3 % slip: 73.4 gpm displacement, 300 ft/min plunger speed, 95.6 % volumetric efficiency, 70.2 gpm delivered and 53.3 kW input at 90 % mechanical efficiency.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Karassik, Messina, Cooper and Heald, Pump Handbook, 4th ed. (McGraw-Hill, 2008), sec. 3.1, power pump theory (displacement, slip, volumetric and mechanical efficiency, torque)