FireCADCalc

Borewell Submersible Pump Head and Power

Total head and motor power of a borewell submersible pump from water level, drawdown, delivery height, pipe size and length, and flow, with Hazen–Williams friction.

Inputs

Examples: Illustrative 6 m3/h borewellDeep farm borewellShallow domestic

Accepted: 0.036 to 1,800 m³/h
Accepted: 0 to 500 m
Accepted: 0 to 200 m
Accepted: 0 to 200 m
Accepted: 1 to 5,000 m
Accepted: 10 to 500 mm
Accepted: 60 to 160
Accepted: 0 to 100 m
Accepted: 20 to 90 %

Results

A submersible pump lifts water from the pumping water level (static level plus drawdown) to the delivery point, and overcomes friction in the column and delivery pipes. Friction uses the Hazen–Williams formula h_f = 10.67 L Q^1.852/(C^1.852 d^4.87) with C about 140 for HDPE or PVC and 100–120 for old steel. Choose a pump whose curve passes through this flow and head, and check the borewell's yield: if drawdown keeps increasing, the flow is too high for the well.

Pipe friction head3.1106m
Total head40.111m
Pipe velocity1.0964m/s
Motor input power0.54523kW
Motor power in horsepower0.73116hp

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative 6 m3/h borewell. The inputs, in the units selected above:

InputValue
Flow6.0000 m³/h
Static water level below ground60.000 m
Drawdown while pumping15.000 m
Delivery height above ground (tank inlet)12.000 m
Total pipe length (column pipe plus delivery)110.00 m
Pipe inside diameter38.100 mm
Hazen–Williams coefficient140.00 -
Fittings and residual head3.0000 m
Pump and motor efficiency45.000 %

Applying the formula below gives:

ResultValue
Pipe friction head7.2653 m
Total head97.265 m
Pipe velocity1.4619 m/s
Motor input power3.5257 kW
Motor power in horsepower4.7280 hp

Open this example in the calculator and change any input.

Formula

\(H = h_s + h_d + h_t + h_f + h_m, \quad h_f = \frac{10.67\,L\,\dot V^{1.852}}{C^{1.852} d^{4.87}}, \quad P = \frac{\rho g\dot V H}{\eta}\)

Variables

Symbol Meaning SI unit
\(\dot V\) Flow m³/s
\(h_s\) Static water level below ground m
\(h_d\) Drawdown while pumping m
\(h_t\) Delivery height above ground (tank inlet) m
\(L\) Total pipe length (column pipe plus delivery) m
\(d\) Pipe inside diameter m
\(C\) Hazen–Williams coefficient -
\(h_m\) Fittings and residual head m
\(\eta\) Pump and motor efficiency -
\(h_f\) Pipe friction head m
\(H\) Total head m
\(v\) Pipe velocity m/s
\(P\) Motor input power W
\(P_{hp}\) Motor power in horsepower W

Method and standards

Borewell pump.

Where it is used

  • Farm, domestic and industrial borewells.
  • Pump replacement and energy audits.

Common mistakes

  • Forgetting drawdown.
  • Using the casing size as the pipe size.

Assumptions and limits

  • Water at about 20 °C; steady pumping level.

References

  • Hazen–Williams formula (SI form)

Questions and answers

What head does a borewell pump need?

Water level plus drawdown plus the height to the tank plus pipe friction: about 97 m for the defaults.

Why does the pipe size matter?

Friction rises steeply as the pipe gets smaller: halving the diameter raises it about 29 times.

What do the defaults represent?

An illustrative 6 m³/h borewell with water at 60 m, 15 m drawdown, a tank 12 m high and 110 m of 38 mm pipe.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.