Worked example
Example: Illustrative 6 m3/h borewell. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Flow | 6.0000 m³/h |
| Static water level below ground | 60.000 m |
| Drawdown while pumping | 15.000 m |
| Delivery height above ground (tank inlet) | 12.000 m |
| Total pipe length (column pipe plus delivery) | 110.00 m |
| Pipe inside diameter | 38.100 mm |
| Hazen–Williams coefficient | 140.00 - |
| Fittings and residual head | 3.0000 m |
| Pump and motor efficiency | 45.000 % |
Applying the formula below gives:
| Result | Value |
|---|---|
| Pipe friction head | 7.2653 m |
| Total head | 97.265 m |
| Pipe velocity | 1.4619 m/s |
| Motor input power | 3.5257 kW |
| Motor power in horsepower | 4.7280 hp |
Open this example in the calculator and change any input.
Formula
\(H = h_s + h_d + h_t + h_f + h_m, \quad h_f = \frac{10.67\,L\,\dot V^{1.852}}{C^{1.852} d^{4.87}}, \quad P = \frac{\rho g\dot V H}{\eta}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\dot V\) | Flow | m³/s |
| \(h_s\) | Static water level below ground | m |
| \(h_d\) | Drawdown while pumping | m |
| \(h_t\) | Delivery height above ground (tank inlet) | m |
| \(L\) | Total pipe length (column pipe plus delivery) | m |
| \(d\) | Pipe inside diameter | m |
| \(C\) | Hazen–Williams coefficient | - |
| \(h_m\) | Fittings and residual head | m |
| \(\eta\) | Pump and motor efficiency | - |
| \(h_f\) | Pipe friction head | m |
| \(H\) | Total head | m |
| \(v\) | Pipe velocity | m/s |
| \(P\) | Motor input power | W |
| \(P_{hp}\) | Motor power in horsepower | W |
Method and standards
Borewell pump.
Where it is used
- Farm, domestic and industrial borewells.
- Pump replacement and energy audits.
Common mistakes
- Forgetting drawdown.
- Using the casing size as the pipe size.
Assumptions and limits
- Water at about 20 °C; steady pumping level.
References
- Hazen–Williams formula (SI form)
Questions and answers
What head does a borewell pump need?
Water level plus drawdown plus the height to the tank plus pipe friction: about 97 m for the defaults.
Why does the pipe size matter?
Friction rises steeply as the pipe gets smaller: halving the diameter raises it about 29 times.
What do the defaults represent?
An illustrative 6 m³/h borewell with water at 60 m, 15 m drawdown, a tank 12 m high and 110 m of 38 mm pipe.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.