FireCADCalc

Spray Nozzle Flow at Pressure, Coverage Width and Nozzle Count

Flow of a spray nozzle at a new pressure from its rated flow, the spray coverage width at a distance and the number of nozzles across a width with overlap.

Inputs

Examples: Illustrative 90 degree spray barWasher, 65 degreeDust suppression, 110 degree

Accepted: 0.0006 to 6,000 L/min
Accepted: 0.1 to 100 bar
Accepted: 0.1 to 100 bar
Accepted: 2.8648 to 177.62 °
Accepted: 0.01 to 10 m
Accepted: 0.01 to 100 m
Accepted: 0 to 80 %

Results

Flow through a nozzle orifice rises with the square root of pressure, Q₂ = Q₁√(p₂/p₁). The theoretical coverage of a spray of angle θ at distance h is 2h tan(θ/2); the actual angle narrows with distance and at low pressure, so overlap neighbouring sprays (20–30 % for flat fans) for even coverage. Spacing is the coverage less the overlap.

Flow at the operating pressure8.1650L/min
Coverage width of one nozzle2,856.3mm
Nozzle spacing2,285.0mm
Nozzles needed across the width3.0000
Total flow24.495L/min

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative 90 degree spray bar. The inputs, in the units selected above:

InputValue
Rated flow2.0000 L/min
Rated pressure3.0000 bar
Operating pressure4.0000 bar
Spray angle90.000 °
Distance from nozzle to target0.30000 m
Width to cover2.0000 m
Overlap between neighbouring sprays30.000 %

Applying the formula below gives:

ResultValue
Flow at the operating pressure2.3094 L/min
Coverage width of one nozzle600.00 mm
Nozzle spacing420.00 mm
Nozzles needed across the width5.0000
Total flow11.547 L/min

Open this example in the calculator and change any input.

Formula

\(Q_2 = Q_1\sqrt{\frac{p_2}{p_1}}, \quad w_c = 2h\tan\frac\theta2, \quad n = \left\lceil\frac{W}{w_c(1 - f_o)}\right\rceil\)

Variables

Symbol Meaning SI unit
\(Q_1\) Rated flow m³/s
\(p_1\) Rated pressure Pa
\(p_2\) Operating pressure Pa
\(\theta\) Spray angle rad
\(h\) Distance from nozzle to target m
\(W\) Width to cover m
\(f_o\) Overlap between neighbouring sprays -
\(Q_2\) Flow at the operating pressure m³/s
\(w_c\) Coverage width of one nozzle m
\(s\) Nozzle spacing m
\(n\) Nozzles needed across the width -
\(Q_t\) Total flow m³/s

Method and standards

Spray nozzles.

Where it is used

  • Washing, cooling, coating and dust suppression.
  • Spray header layout.

Common mistakes

  • Assuming flow is proportional to pressure.
  • Using the nominal angle at long distances.

Assumptions and limits

  • Water-like liquid; nozzle in its normal pressure range.

References

  • Orifice flow scaling and spray geometry

Questions and answers

How does flow change with pressure?

With the square root: doubling pressure gives 41 % more flow.

Why overlap the sprays?

Spray density falls off towards the edges, so overlapping evens out the coverage.

What do the defaults represent?

An illustrative 2 L/min at 3 bar nozzle run at 4 bar, 90° spray 300 mm from a 2 m wide target, 30 % overlap.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.