Worked example
Example: Illustrative 12 kN hot, 25 mm up. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Hot (operating) load | 12.000 kN |
| Thermal movement (+ up, − down) | 25.000 mm |
| Spring rate | 120.00 N/mm |
| Variability limit | 25.000 % |
Applying the formula below gives:
| Result | Value |
|---|---|
| Cold (installed) load | 15.000 kN |
| Load change | 3.0000 kN |
| Variability | 25.000 % |
| Largest spring rate for the limit | 120.00 N/mm |
Open this example in the calculator and change any input.
Formula
\(F_c = F_h + k\Delta y, \quad V = \frac{k|\Delta y|}{F_h}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(F_h\) | Hot (operating) load | N |
| \(\Delta y\) | Thermal movement (+ up, − down) | m |
| \(k\) | Spring rate | N/m |
| \(V_{max}\) | Variability limit | - |
| \(F_c\) | Cold (installed) load | N |
| \(\Delta F\) | Load change | N |
| \(V\) | Variability | - |
| \(k_{max}\) | Largest spring rate for the limit | N/m |
Method and standards
Spring selection.
Where it is used
- Steam and hot oil piping supports.
- Boiler and turbine connecting pipework.
Common mistakes
- Mixing up the sign of the movement.
- Setting the spring for the cold load.
Assumptions and limits
- Linear spring; vertical movement only.
References
- Variable spring support selection
Questions and answers
Why is variability limited?
A large load change shifts weight onto neighbouring supports and equipment nozzles as the pipe heats or cools.
When is a constant-effort hanger needed?
For large vertical movements near sensitive equipment, where even a soft spring would exceed the variability limit.
What do the defaults represent?
An illustrative support carrying 12 kN hot, moving 25 mm up on heating, with a 120 N/mm spring and a 25 % limit.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Nayyar, Piping Handbook, 7th ed. (McGraw-Hill, 2000)