Variable Spring Hanger Load Variation and Selection

Cold (installed) load of a variable spring hanger from the hot load, thermal movement and spring rate, and the load variability against a limit.

Thermal power plantProcess steam and utilitiesRefinery and petrochemical

Inputs

Examples: Illustrative 12 kN hot, 25 mm upMoving down 40 mm, 30 kNLarge move 60 mm needs soft spring

Accepted: 0.1 to 1,000 kN
Accepted: -300 to 300 mm
Accepted: 1 to 100,000 N/mm
Accepted: 5 to 50 %

Results

The spring is set so that it carries the hot load in operation; moving up by Δy unloads it, so the cold load is F_h + kΔy. Variability kΔy/F_h is commonly limited to about 25 %; above that, use a softer spring or a constant-effort hanger.

Cold (installed) load15.000kN
Load change3.0000kN
Variability25.000%
Largest spring rate for the limit120.00N/mm

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative 12 kN hot, 25 mm up. The inputs, in the units selected above:

InputValue
Hot (operating) load12.000 kN
Thermal movement (+ up, − down)25.000 mm
Spring rate120.00 N/mm
Variability limit25.000 %

Applying the formula below gives:

ResultValue
Cold (installed) load15.000 kN
Load change3.0000 kN
Variability25.000 %
Largest spring rate for the limit120.00 N/mm

Open this example in the calculator and change any input.

Formula

\(F_c = F_h + k\Delta y, \quad V = \frac{k|\Delta y|}{F_h}\)

Variables

Symbol Meaning SI unit
\(F_h\) Hot (operating) load N
\(\Delta y\) Thermal movement (+ up, − down) m
\(k\) Spring rate N/m
\(V_{max}\) Variability limit -
\(F_c\) Cold (installed) load N
\(\Delta F\) Load change N
\(V\) Variability -
\(k_{max}\) Largest spring rate for the limit N/m

Method and standards

Spring selection.

Where it is used

  • Steam and hot oil piping supports.
  • Boiler and turbine connecting pipework.

Common mistakes

  • Mixing up the sign of the movement.
  • Setting the spring for the cold load.

Assumptions and limits

  • Linear spring; vertical movement only.

References

  • Variable spring support selection

Questions and answers

Why is variability limited?

A large load change shifts weight onto neighbouring supports and equipment nozzles as the pipe heats or cools.

When is a constant-effort hanger needed?

For large vertical movements near sensitive equipment, where even a soft spring would exceed the variability limit.

What do the defaults represent?

An illustrative support carrying 12 kN hot, moving 25 mm up on heating, with a 120 N/mm spring and a 25 % limit.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Nayyar, Piping Handbook, 7th ed. (McGraw-Hill, 2000)

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.