FireCADCalc

Economic (Optimum) Pipe Diameter for Liquids and Gases

Economic (optimum) pipe diameter for turbulent flow from carbon steel and stainless steel cost equations, with the resulting velocity and Reynolds number.

Process steam and utilitiesRefinery and petrochemicalChemical and fertiliser

Inputs

Examples: Light oil 25 t/h, 820 kg/m3, 2 mPa s, carbon steel

Accepted: 0.0001 to 10,000 kg/s
Accepted: 0.05 to 2,500 kg/m³
Accepted: 0.001 to 1,000 mPa·s

Results

Choose the nearest standard pipe size. The equations reflect typical installed pipe and power costs and are valid for turbulent flow; do not use them for steam or two-phase lines.

Optimum inside diameter68.364mm
Volume flow30.488m³/h
Velocity at the optimum diameter2.3072m/s
Reynolds number64,669

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Light oil 25 t/h, 820 kg/m3, 2 mPa s, carbon steel. The inputs, in the units selected above:

InputValue
Mass flow6.9444 kg/s
Fluid density820.00 kg/m³
Fluid viscosity (for the flow check)2.0000 mPa·s
MethodCarbon steel cost equation

Applying the formula below gives:

ResultValue
Optimum inside diameter68.364 mm
Volume flow30.488 m³/h
Velocity at the optimum diameter2.3072 m/s
Reynolds number64,669

Open this example in the calculator and change any input.

Formula

\(d_{opt} = 293\,G^{0.53}\rho^{-0.37}\ \text{mm (carbon steel)}, \quad d_{opt} = 260\,G^{0.52}\rho^{-0.37}\ \text{mm (stainless)}\)

\(D_{opt} = 0.363\,Q^{0.45}\rho^{0.13}\ \text{m (alternative form, } Q\text{ in m³/s)}\)

Variables

Symbol Meaning SI unit
\(G\) Mass flow kg/s
\(\rho\) Fluid density kg/m³
\(\mu\) Fluid viscosity (for the flow check) Pa·s
\(\text{method}\) Method -
\(d_{opt}\) Optimum inside diameter m
\(Q\) Volume flow m³/s
\(u\) Velocity at the optimum diameter m/s
\(Re\) Reynolds number -

Method and standards

Empirical optimum-diameter equations balancing pipe cost against pumping cost.

Where it is used

  • First line sizing on process flow diagrams.
  • Checking existing lines for gross over- or undersizing.

Common mistakes

  • Using them for steam or slurry lines.
  • Taking the result without checking pressure drop and NPSH.

Assumptions and limits

  • Turbulent flow; typical cost ratios built into the constants.

Questions and answers

Why does density appear with a negative exponent?

Lighter fluids need more volume per kilogram, so the cost-optimal diameter for the same mass flow is larger.

Why do the methods differ?

They assume different installed pipe costs and power prices; the low installation factor gives larger diameters.

What do the defaults represent?

An illustrative case: Light oil 25 t/h, 820 kg/m3, 2 mPa s, carbon steel. Replace the inputs with your own data.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Sinnott, Coulson and Richardson's Chemical Engineering Vol. 6: Chemical Engineering Design, 4th ed. (Elsevier, 2005), sec. 5.6, eqs. 5.14 and 5.15, Examples 5.6 and 5.7; Peters and Timmerhaus, Plant Design and Economics for Chemical Engineers, 4th ed. (1991)

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.