Worked example
Example: Illustrative 20 in pipeline at 100 bar, 15 C. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Pipe outside diameter | 508.00 mm |
| Wall thickness | 12.700 mm |
| Test pressure (gauge) | 100.00 bar |
| Water temperature | 15.000 °C |
| Elastic modulus of steel | 207.00 GPa |
| Poisson's ratio | 0.30000 - |
| Linear thermal expansion of steel | 11.700 µm/(m·K) |
| Temperature change during the test | 1.0000 K |
Applying the formula below gives:
| Result | Value |
|---|---|
| Volumetric thermal expansion of the water | 169.86 µm/(m·K) |
| Compressibility of the water | 4.5530e-04 1/MPa |
| Pressure change per kelvin | 2.3206 bar |
| Pressure change for the temperature change | 2.3206 bar |
Open this example in the calculator and change any input.
Formula
\(\frac{\Delta p}{\Delta T} = \frac{B - 2A}{\dfrac{D(1-\nu^2)}{E\,t} + C}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(D\) | Pipe outside diameter | m |
| \(t\) | Wall thickness | m |
| \(p\) | Test pressure (gauge) | Pa |
| \(T_w\) | Water temperature | K |
| \(E\) | Elastic modulus of steel | Pa |
| \(\nu\) | Poisson's ratio | - |
| \(A\) | Linear thermal expansion of steel | 1/K |
| \(\Delta T\) | Temperature change during the test | K |
| \(B\) | Volumetric thermal expansion of the water | 1/K |
| \(C\) | Compressibility of the water | 1/Pa |
| \(\Delta p/\Delta T\) | Pressure change per kelvin | Pa |
| \(\Delta p\) | Pressure change for the temperature change | Pa |
Method and standards
Hydrotest temperature correction.
Where it is used
- Pipeline hydrostatic test records.
- Judging pressure loss in hold tests.
Common mistakes
- Ignoring water temperature during a long hold.
- Using the steel's volumetric expansion 3A for a restrained pipeline.
Assumptions and limits
- Long restrained pipe full of air-free water; thin wall.
References
- Pressure–temperature relation of a restrained water-filled pipe (B − 2A)/(D(1 − ν²)/Et + C)
- IAPWS-IF97 water density
- expansion and compressibility
Questions and answers
Why did my hydrotest pressure drop overnight without a leak?
The water cooled: at about 15 °C a 1 K drop lowers the pressure by roughly 2 bar in a 20 in, 12.7 mm pipe.
Why does the effect vanish near 4 °C?
Water has its greatest density at about 4 °C, so its expansion coefficient is nearly zero there.
What do the defaults represent?
An illustrative 20 in (508 × 12.7 mm) pipeline tested at 100 bar(g) with water at 15 °C.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.